{"id":"https://openalex.org/W1908249149","doi":null,"title":"Overvoltage surge in low voltage consumer equipment","display_name":"Overvoltage surge in low voltage consumer equipment","publication_year":2012,"publication_date":"2012-01-01","ids":{"openalex":"https://openalex.org/W1908249149","mag":"1908249149"},"language":"en","primary_location":{"id":"mag:1908249149","doi":null,"is_oa":false,"landing_page_url":"http://eprints.utm.my/id/eprint/32351/","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"volume":null,"type":"dissertation","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5001663757","display_name":"Nor Azman Yaakob","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Nor Azman Yaakob","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5001663757"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10787","display_name":"Lightning and Electromagnetic Phenomena","score":0.698199987411499,"subfield":{"id":"https://openalex.org/subfields/1902","display_name":"Atmospheric Science"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10787","display_name":"Lightning and Electromagnetic Phenomena","score":0.698199987411499,"subfield":{"id":"https://openalex.org/subfields/1902","display_name":"Atmospheric Science"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.2734000086784363,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11444","display_name":"Electromagnetic Compatibility and Noise Suppression","score":0.015599999576807022,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transient-overvoltage","display_name":"transient overvoltage","score":0.859000027179718},{"id":"https://openalex.org/keywords/surge-protection-devices","display_name":"surge protective devices","score":0.9739999771118164},{"id":"https://openalex.org/keywords/electrical-overstress","display_name":"electrical overstress","score":0.777999997138977},{"id":"https://openalex.org/keywords/power-quality","display_name":"power quality","score":0.6570000052452087},{"id":"https://openalex.org/keywords/distribution-transformers","display_name":"distribution transformers","score":0.7490000128746033},{"id":"https://openalex.org/keywords/overvoltage-protection","display_name":"overvoltage protection","score":0.6299999952316284}],"concepts":[{"id":"https://openalex.org/C15703209","wikidata":"https://www.wikidata.org/wiki/Q333883","display_name":"Overvoltage","level":3,"score":0.9404966831207275},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.6992395520210266},{"id":"https://openalex.org/C128624480","wikidata":"https://www.wikidata.org/wiki/Q1504817","display_name":"Low voltage","level":3,"score":0.6710071563720703},{"id":"https://openalex.org/C154108245","wikidata":"https://www.wikidata.org/wiki/Q287381","display_name":"Surge","level":2,"score":0.6572480201721191},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.6487417221069336},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5533372163772583},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5301873087882996},{"id":"https://openalex.org/C162175671","wikidata":"https://www.wikidata.org/wiki/Q3749263","display_name":"Electrical equipment","level":2,"score":0.45684659481048584},{"id":"https://openalex.org/C14915586","wikidata":"https://www.wikidata.org/wiki/Q1653998","display_name":"Transient voltage suppressor","level":3,"score":0.44029417634010315},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.41978222131729126},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.15517884492874146},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:1908249149","doi":null,"is_oa":false,"landing_page_url":"http://eprints.utm.my/id/eprint/32351/","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.5378999710083008}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2473473843","https://openalex.org/W1884867246","https://openalex.org/W1999694264","https://openalex.org/W4312547055","https://openalex.org/W1515480189","https://openalex.org/W7043995260","https://openalex.org/W7098741107","https://openalex.org/W1584404213","https://openalex.org/W7096323224","https://openalex.org/W2056973844"],"abstract_inverted_index":{"These":[0],"papers":[1],"present":[2],"the":[3,6,17,26,40,53,59,112,120,124,132,140,155,166,184,192,197,201,204,212,221,262],"study":[4,154],"on":[5,87,96],"effects":[7],"of":[8,19,28,47,81,114,123,157,200,220,225,251],"Overvoltage":[9,62],"Surges":[10,63],"in":[11,38,52,190,259,261],"low":[12,97,141,247],"voltage":[13,98,142,248,264],"consumer":[14,99,249],"equipment":[15,94,100,193],"by":[16],"use":[18],"PSCAD":[20],"software":[21],"simulation.":[22],"In":[23,111,136],"this":[24,147],"approach,":[25],"combination":[27],"Shock":[29],"Protection":[30],"Devices":[31,160],"installed":[32,51,161],"at":[33,129,162],"different":[34],"locations":[35,46,164,169,199,222],"will":[36],"result":[37],"ascertaining":[39],"most":[41],"suitable":[42,198],"numbers":[43,224],"and":[44,107,145,179,223,234],"appropriate":[45],"SPDs":[48,202,226,241],"to":[49,92,138,153,207,245,266],"be":[50,66,69,208,228],"safe":[54],"protection":[55],"zone":[56],"away":[57,182],"from":[58,165,183],"surge":[60,126,195],"origin.":[61],"can":[64],"neither":[65],"destroyed":[67],"nor":[68],"prevented.":[70],"Also":[71],"commonly":[72],"known":[73],"as":[74,102],"Transient":[75],"Overvoltage,":[76],"it":[77],"is":[78,85,127,149,196],"a":[79],"type":[80],"electrical":[82,93,143,252],"overstress":[83],"that":[84,117,240],"conducted":[86],"wires":[88],"which":[89],"brings":[90],"damage":[91],"especially":[95],"such":[101],"computers,":[103],"modems,":[104],"electronic":[105],"devices":[106,116],"even":[108],"electric":[109],"motors.":[110],"absence":[113],"protective":[115],"could":[118],"limit":[119],"voltage,":[121],"magnitude":[122],"peak":[125],"usually":[128],"least":[130],"twice":[131],"normal":[133],"system":[134,254],"voltage.":[135],"order":[137],"protect":[139,246],"installations":[144,265],"equipment,":[146],"project":[148],"being":[150],"carried":[151],"out":[152],"effectiveness":[156],"Surge":[158],"Protective":[159],"various":[163],"load.":[167],"The":[168,187],"are":[170,237,242],"0":[171],"metres,":[172,174,176],"100":[173],"200":[175],"300":[177],"metres":[178,181],"400":[180],"distribution":[185,253],"transformer.":[186],"essential":[188,244],"criteria":[189],"protecting":[191,211],"during":[194],"besides":[203],"optimum":[205],"quantity":[206],"introduced":[209],"for":[210],"Low":[213],"Voltage":[214],"Consumer":[215],"equipment.":[216],"Thus,":[217],"proper":[218],"selection":[219],"must":[227],"really":[229],"put":[230],"into":[231],"consideration.":[232],"Simulation":[233],"experimental":[235],"results":[236],"presented":[238],"demonstrated":[239],"also":[243],"segment":[250],"although":[255],"presently":[256],"they":[257],"were":[258],"existence":[260],"high":[263],"improve":[267],"power":[268],"quality.":[269]},"counts_by_year":[],"updated_date":"2025-11-06T04:12:42.849631","created_date":"2016-06-24T00:00:00"}
