{"id":"https://openalex.org/W1892455352","doi":"https://doi.org/10.1109/apec.1998.654019","title":"Even-harmonics concerns at an industrial facility using a large number of half-controlled rectifiers","display_name":"Even-harmonics concerns at an industrial facility using a large number of half-controlled rectifiers","alternate_titles":[],"publication_year":2002,"publication_date":"2002-11-27","ids":{"openalex":"https://openalex.org/W1892455352","doi":"https://doi.org/10.1109/apec.1998.654019","mag":"1892455352"},"language":"en","primary_location":{"id":"doi:10.1109/apec.1998.654019","doi":"https://doi.org/10.1109/apec.1998.654019","is_oa":false,"landing_page_url":"https://doi.org/10.1109/apec.1998.654019","pdf_url":null,"source":{"id":"https://openalex.org/S4210177957","display_name":"Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition","issn_l":"1048-2334","issn":["1048-2334","2470-6647"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"APEC '98 Thirteenth Annual Applied Power Electronics Conference and Exposition","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W1892455352"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5009581190","display_name":"A. Mansoor","orcid":"https://orcid.org/0009-0001-3809-6998","observed_orcids":["https://orcid.org/0009-0001-3809-6998"]},"institutions":[{"id":"https://openalex.org/I1335486098","display_name":"Electric Power Research Institute","ror":"https://ror.org/02dqztz06","country_code":"US","type":"nonprofit","lineage":["https://openalex.org/I1335486098"]}],"countries":["US"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"A. Mansoor","raw_affiliation_strings":["Applications Center, EPRI Power Electronics, Knoxville, TN, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Applications Center, EPRI Power Electronics, Knoxville, TN, USA","institution_ids":["https://openalex.org/I1335486098"]}]},{"author_position":"middle","author":{"id":null,"display_name":"J. McGee","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"J. McGee","raw_affiliation_strings":["Duke Power Company, Greenville, SC, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Duke Power Company, Greenville, SC, USA","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101495341","display_name":"Fang Zheng Peng","orcid":"https://orcid.org/0000-0003-0827-333X","observed_orcids":["https://orcid.org/0000-0003-0827-333X"]},"institutions":[{"id":"https://openalex.org/I1289243028","display_name":"Oak Ridge National Laboratory","ror":"https://ror.org/01qz5mb56","country_code":"US","type":"facility","lineage":["https://openalex.org/I1289243028","https://openalex.org/I1330989302","https://openalex.org/I39565521","https://openalex.org/I4210159294"]}],"countries":["US"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"F.Z. Peng","raw_affiliation_strings":["Oak Ridge National Laboratory, Oak Ridge, TN, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Oak Ridge National Laboratory, Oak Ridge, TN, USA","institution_ids":["https://openalex.org/I1289243028"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.7188,"has_fulltext":false,"cited_by_count":7,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.61113901,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":94},"biblio":{"volume":"2","issue":null,"first_page":"994","last_page":"1000"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11444","display_name":"Electromagnetic Compatibility and Noise Suppression","score":0.0006000000284984708,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/harmonic-interaction","display_name":"harmonic interaction","score":0.671999990940094},{"id":"https://openalex.org/keywords/hvac-systems","display_name":"HVAC systems","score":0.6200000047683716},{"id":"https://openalex.org/keywords/air-handling-systems","display_name":"air handling systems","score":0.6510000228881836},{"id":"https://openalex.org/keywords/harmonic-spectrum-analysis","display_name":"harmonic spectrum analysis","score":0.5189999938011169},{"id":"https://openalex.org/keywords/current-and-voltage-waveforms","display_name":"voltage and current waveforms","score":0.7889999747276306},{"id":"https://openalex.org/keywords/industrial-power-quality","display_name":"industrial power quality","score":0.703000009059906}],"concepts":[{"id":"https://openalex.org/C188414643","wikidata":"https://www.wikidata.org/wiki/Q3001183","display_name":"Harmonics","level":3,"score":0.8069368600845337},{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.7934632897377014},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.7031493186950684},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.5845993757247925},{"id":"https://openalex.org/C127934551","wikidata":"https://www.wikidata.org/wiki/Q1148098","display_name":"Harmonic","level":2,"score":0.5542638301849365},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.5484004616737366},{"id":"https://openalex.org/C131770355","wikidata":"https://www.wikidata.org/wiki/Q876215","display_name":"Harmonic analysis","level":2,"score":0.5382556319236755},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5250111222267151},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5209290385246277},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.4277704358100891},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3951941430568695},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.38631072640419006},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.37835994362831116},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.35611575841903687},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.25130337476730347},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.2277645766735077},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.22340965270996094}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/apec.1998.654019","doi":"https://doi.org/10.1109/apec.1998.654019","is_oa":false,"landing_page_url":"https://doi.org/10.1109/apec.1998.654019","pdf_url":null,"source":{"id":"https://openalex.org/S4210177957","display_name":"Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition","issn_l":"1048-2334","issn":["1048-2334","2470-6647"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"APEC '98 Thirteenth Annual Applied Power Electronics Conference and Exposition","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.5378999710083008}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W626941064","https://openalex.org/W1854161196","https://openalex.org/W2006287587","https://openalex.org/W2047641301","https://openalex.org/W2153461155"],"related_works":["https://openalex.org/W1860770027","https://openalex.org/W2257754247","https://openalex.org/W2002696585","https://openalex.org/W1765543430","https://openalex.org/W4254591832","https://openalex.org/W2006519131","https://openalex.org/W3144254564","https://openalex.org/W2044859450","https://openalex.org/W2025584852","https://openalex.org/W4239031339"],"abstract_inverted_index":{"This":[0],"paper":[1],"documents":[2],"a":[3,12],"case":[4],"study":[5],"at":[6],"an":[7],"industrial":[8],"facility":[9],"that":[10,39,52],"uses":[11],"large":[13],"number":[14],"of":[15],"half-controlled":[16],"heater":[17],"drives.":[18],"Voltage":[19],"and":[20,65,78],"current":[21],"waveforms,":[22],"along":[23],"with":[24],"harmonic":[25,36],"spectrums,":[26],"are":[27,69],"gathered":[28],"from":[29,76],"different":[30],"locations":[31],"within":[32,61],"the":[33,43,56,62,73],"facility.":[34],"A":[35],"interaction":[37],"problem":[38],"caused":[40],"failures":[41],"in":[42,55],"pulse":[44],"width":[45],"modulated":[46],"adjustable":[47],"speed":[48],"drives":[49],"(PWM":[50],"ASDs)":[51],"were":[53],"installed":[54],"existing":[57],"air":[58],"handling":[59],"equipment":[60],"heating":[63],"ventilation":[64],"air-conditioning":[66],"(HVAC)":[67],"system":[68],"analyzed":[70],"by":[71],"using":[72],"results":[74],"obtained":[75],"measurements":[77],"modeling.":[79]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W1892455352","counts_by_year":[{"year":2022,"cited_by_count":2},{"year":2012,"cited_by_count":1}],"updated_date":"2026-11-14T11:04:58.165337","created_date":"2016-06-24T00:00:00"}
