{"id":"https://openalex.org/W187040147","doi":"https://doi.org/10.13182/nt89-a34332","title":"Probabilistic Risk Assessment Based Guidance for Piping In-Service Inspection","display_name":"Probabilistic Risk Assessment Based Guidance for Piping In-Service Inspection","publication_year":1989,"publication_date":"1989-12-02","ids":{"openalex":"https://openalex.org/W187040147","doi":"https://doi.org/10.13182/nt89-a34332","mag":"187040147"},"language":"en","primary_location":{"id":"doi:10.13182/nt89-a34332","doi":"https://doi.org/10.13182/nt89-a34332","is_oa":false,"landing_page_url":"https://doi.org/10.13182/nt89-a34332","pdf_url":null,"source":{"id":"https://openalex.org/S190997038","display_name":"Nuclear Technology","issn_l":"0029-5450","issn":["0029-5450","1943-7471"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-100","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Nuclear Technology","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5112297286","display_name":"Truong V. Vo","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I142606810","display_name":"Pacific Northwest National Laboratory","ror":"https://ror.org/05h992307","country_code":"US","type":"facility","lineage":["https://openalex.org/I1325736334","https://openalex.org/I1330989302","https://openalex.org/I142606810","https://openalex.org/I39565521"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Truong V. Vo","raw_affiliation_strings":["Pacific Northwest Laboratory P.O. Box 999, Richland, Washington 99352"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Pacific Northwest Laboratory P.O. Box 999, Richland, Washington 99352","institution_ids":["https://openalex.org/I142606810"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108389275","display_name":"Bryan F. Gore","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I142606810","display_name":"Pacific Northwest National Laboratory","ror":"https://ror.org/05h992307","country_code":"US","type":"facility","lineage":["https://openalex.org/I1325736334","https://openalex.org/I1330989302","https://openalex.org/I142606810","https://openalex.org/I39565521"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Bryan F. Gore","raw_affiliation_strings":["Pacific Northwest Laboratory P.O. Box 999, Richland, Washington 99352"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Pacific Northwest Laboratory P.O. Box 999, Richland, Washington 99352","institution_ids":["https://openalex.org/I142606810"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5048774130","display_name":"Elizabeth J. Eschbach","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I142606810","display_name":"Pacific Northwest National Laboratory","ror":"https://ror.org/05h992307","country_code":"US","type":"facility","lineage":["https://openalex.org/I1325736334","https://openalex.org/I1330989302","https://openalex.org/I142606810","https://openalex.org/I39565521"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Elizabeth J. Eschbach","raw_affiliation_strings":["Pacific Northwest Laboratory P.O. Box 999, Richland, Washington 99352"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Pacific Northwest Laboratory P.O. Box 999, Richland, Washington 99352","institution_ids":["https://openalex.org/I142606810"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5109840960","display_name":"F.A. Simonen","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I142606810","display_name":"Pacific Northwest National Laboratory","ror":"https://ror.org/05h992307","country_code":"US","type":"facility","lineage":["https://openalex.org/I1325736334","https://openalex.org/I1330989302","https://openalex.org/I142606810","https://openalex.org/I39565521"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Fredric A. Simonen","raw_affiliation_strings":["Pacific Northwest Laboratory P.O. Box 999, Richland, Washington 99352"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Pacific Northwest Laboratory P.O. Box 999, Richland, Washington 99352","institution_ids":["https://openalex.org/I142606810"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I142606810"],"apc_list":null,"apc_paid":null,"fwci":4.9594,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.92100324,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":95,"max":96},"biblio":{"volume":"88","issue":"1","first_page":"13","last_page":"20"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.5,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.5,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12086","display_name":"Structural Integrity and Reliability Analysis","score":0.4081999957561493,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13923","display_name":"Nuclear and radioactivity studies","score":0.04560000076889992,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/probabilistic-risk-assessment","display_name":"probabilistic risk assessment","score":0.9340000152587891},{"id":"https://openalex.org/keywords/in-service-inspection","display_name":"in-service inspection","score":0.9750000238418579},{"id":"https://openalex.org/keywords/nuclear-power-plant-piping","display_name":"nuclear power plant piping","score":0.5899999737739563},{"id":"https://openalex.org/keywords/inspection-prioritization","display_name":"inspection prioritization","score":0.9150000214576721},{"id":"https://openalex.org/keywords/weld-failure","display_name":"weld failure","score":0.7979999780654907},{"id":"https://openalex.org/keywords/failure-mode-and-effects-analysis","display_name":"failure mode and effects analysis","score":0.9330000281333923},{"id":"https://openalex.org/keywords/pressure-boundary-components","display_name":"pressure boundary components","score":0.7260000109672546},{"id":"https://openalex.org/keywords/inspection-requirements","display_name":"inspection requirements","score":0.4819999933242798},{"id":"https://openalex.org/keywords/asme-boiler-and-pressure-vessel-code","display_name":"ASME Boiler and Pressure Vessel Code","score":0.7990000247955322},{"id":"https://openalex.org/keywords/nuclear-power-plant-safety","display_name":"nuclear power plant safety","score":0.5320000052452087}],"concepts":[{"id":"https://openalex.org/C2779095084","wikidata":"https://www.wikidata.org/wiki/Q3679502","display_name":"Piping","level":2,"score":0.8259720802307129},{"id":"https://openalex.org/C73722673","wikidata":"https://www.wikidata.org/wiki/Q1082833","display_name":"Probabilistic risk assessment","level":3,"score":0.5496885180473328},{"id":"https://openalex.org/C131721965","wikidata":"https://www.wikidata.org/wiki/Q740460","display_name":"Pressure vessel","level":2,"score":0.5237990617752075},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.5224803686141968},{"id":"https://openalex.org/C49937458","wikidata":"https://www.wikidata.org/wiki/Q2599292","display_name":"Probabilistic logic","level":2,"score":0.5175908803939819},{"id":"https://openalex.org/C12174686","wikidata":"https://www.wikidata.org/wiki/Q1058438","display_name":"Risk assessment","level":2,"score":0.465705931186676},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.46173202991485596},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4528036415576935},{"id":"https://openalex.org/C6441794","wikidata":"https://www.wikidata.org/wiki/Q1420867","display_name":"Eddy-current testing","level":3,"score":0.42980048060417175},{"id":"https://openalex.org/C2780378061","wikidata":"https://www.wikidata.org/wiki/Q25351891","display_name":"Service (business)","level":2,"score":0.4132933020591736},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.41056957840919495},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.35802704095840454},{"id":"https://openalex.org/C77595967","wikidata":"https://www.wikidata.org/wiki/Q3151013","display_name":"Forensic engineering","level":1,"score":0.3441799283027649},{"id":"https://openalex.org/C107053488","wikidata":"https://www.wikidata.org/wiki/Q2674423","display_name":"Construction engineering","level":1,"score":0.33359140157699585},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.19547539949417114},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.18428564071655273},{"id":"https://openalex.org/C131357438","wikidata":"https://www.wikidata.org/wiki/Q208598","display_name":"Eddy current","level":2,"score":0.15498989820480347},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.12837010622024536},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C162853370","wikidata":"https://www.wikidata.org/wiki/Q39809","display_name":"Marketing","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.13182/nt89-a34332","doi":"https://doi.org/10.13182/nt89-a34332","is_oa":false,"landing_page_url":"https://doi.org/10.13182/nt89-a34332","pdf_url":null,"source":{"id":"https://openalex.org/S190997038","display_name":"Nuclear Technology","issn_l":"0029-5450","issn":["0029-5450","1943-7471"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-100","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Nuclear Technology","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320338347","display_name":"Idaho National Laboratory","ror":"https://ror.org/00ty2a548"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":2,"referenced_works":["https://openalex.org/W1580430730","https://openalex.org/W4361804966"],"related_works":["https://openalex.org/W49379373","https://openalex.org/W2029126451","https://openalex.org/W222564538","https://openalex.org/W2476008380","https://openalex.org/W2345552589","https://openalex.org/W1948471740","https://openalex.org/W346199051","https://openalex.org/W168189774","https://openalex.org/W1993331897","https://openalex.org/W262835985"],"abstract_inverted_index":{"Some":[0],"of":[1,4,54,66,79,90,105,144,154],"the":[2,5,12,39,51,67,75,88,100,106,111,120,139,145,152],"goals":[3],"Nondestructive":[6],"Evaluation":[7],"Reliability":[8],"Program":[9],"sponsored":[10],"by":[11],"U.S.":[13],"Nuclear":[14],"Regulatory":[15],"Commission":[16],"at":[17],"Pacific":[18],"Northwest":[19],"Laboratory":[20],"are":[21,41,114],"to":[22,34,38,46,82,116,135,161,176],"assess":[23],"current":[24],"inspection":[25,85],"requirements":[26,40],"for":[27,49,124,166],"all":[28],"pressure":[29],"boundary":[30],"systems":[31,123,168],"and":[32,58,62,77,99,118,128,137,169],"components,":[33],"determine":[35],"whether":[36],"improvements":[37],"needed,":[42],"and,":[43],"if":[44],"necessary,":[45],"develop":[47],"recommendations":[48],"revising":[50],"American":[52],"Society":[53],"Mechanical":[55],"Engineers":[56],"Boiler":[57],"Pressure":[59],"Vessel":[60],"Code":[61],"regulatory":[63],"requirements.":[64],"Part":[65],"work":[68],"performed":[69],"in":[70,110],"addressing":[71],"this":[72,155,157],"goal":[73],"was":[74],"development":[76],"demonstration":[78],"a":[80,163],"method":[81,158],"establish":[83],"in-service":[84],"priorities":[86],"through":[87],"use":[89],"probabilistic":[91],"risk":[92],"assessment":[93],"(PRA)":[94],"results.":[95],"The":[96],"Oconee-3":[97,146],"PRA":[98],"observed":[101],"weld":[102],"failure":[103],"data":[104],"nuclear":[107],"plants":[108],"operating":[109],"United":[112],"States":[113],"used":[115,134],"identify":[117,136],"prioritize":[119,138],"most":[121,140],"risk-important":[122],"inspection.":[125],"Failure":[126],"modes":[127],"effects":[129],"analysis":[130],"methodology":[131],"is":[132,159],"then":[133],"riskimportant":[141],"piping":[142,170],"sections":[143,171],"emergency":[147],"feedwater":[148],"system.":[149],"Based":[150],"on":[151],"results":[153],"study,":[156],"demonstrated":[160],"be":[162,177],"useful":[164],"tool":[165],"identifying":[167],"or":[172],"welds":[173],"that":[174],"need":[175],"inspected.":[178]},"counts_by_year":[{"year":2026,"cited_by_count":2}],"updated_date":"2026-10-01T08:54:57.152042","created_date":"2016-06-24T00:00:00"}
