{"id":"https://openalex.org/W1861635876","doi":null,"title":"To Resolve The Voltage Unbalance Of The Dc Links In Different H-Bridges Based Solid State Transformer (Sst)","display_name":"To Resolve The Voltage Unbalance Of The Dc Links In Different H-Bridges Based Solid State Transformer (Sst)","alternate_titles":[],"publication_year":2015,"publication_date":"2015-02-01","ids":{"openalex":"https://openalex.org/W1861635876","mag":"1861635876"},"language":"en","primary_location":{"id":"pmh:oai:ojs.ijrcct.org:article/1035","doi":null,"is_oa":false,"landing_page_url":"http://ijrcct.org/index.php/ojs/article/view/1035","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"IJRCCT; Vol 4, No 1 (2015): January; 072-076","raw_type":"Peer-reviewed Article"},"parent_works":[],"lineage":["https://openalex.org/W1861635876"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Jyotsna, Peravali","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Jyotsna, Peravali","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"4","issue":"1","first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.8618000149726868,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.8618000149726868,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.12300000339746475,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.00839999970048666,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/solid-state-transformer","display_name":"solid-state transformer","score":0.9990000128746033},{"id":"https://openalex.org/keywords/cascaded-h-bridge-multilevel-converter","display_name":"cascaded H-bridge converter","score":0.9039999842643738},{"id":"https://openalex.org/keywords/dual-active-bridge-converter","display_name":"dual active bridge converter","score":0.9789999723434448},{"id":"https://openalex.org/keywords/high-frequency-transformer","display_name":"high-frequency transformer","score":0.718999981880188},{"id":"https://openalex.org/keywords/ac-dc-rectifier","display_name":"AC-DC rectifier","score":0.8050000071525574},{"id":"https://openalex.org/keywords/dc-ac-inverter","display_name":"DC-AC inverter","score":0.7889999747276306},{"id":"https://openalex.org/keywords/dc-power-distribution","display_name":"DC distribution systems","score":0.7059999704360962},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"distributed generation","score":0.6179999709129333},{"id":"https://openalex.org/keywords/bidirectional-power-flow","display_name":"bidirectional power flow","score":0.75},{"id":"https://openalex.org/keywords/voltage-sag-compensation","display_name":"voltage sag compensation","score":0.652999997138977},{"id":"https://openalex.org/keywords/fault-isolation","display_name":"fault isolation","score":0.6079999804496765},{"id":"https://openalex.org/keywords/power-factor-correction","display_name":"power factor correction","score":0.6869999766349792},{"id":"https://openalex.org/keywords/harmonic-isolation","display_name":"harmonic isolation","score":0.7839999794960022}],"concepts":[{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5662209391593933},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5504943132400513},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5475829243659973},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.5095136761665344},{"id":"https://openalex.org/C180850520","wikidata":"https://www.wikidata.org/wiki/Q2166404","display_name":"Isolation transformer","level":4,"score":0.49190258979797363},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.4871499240398407},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.44952574372291565},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.43105411529541016},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.43076297640800476},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.429830402135849},{"id":"https://openalex.org/C55118286","wikidata":"https://www.wikidata.org/wiki/Q634739","display_name":"Forward converter","level":4,"score":0.41237232089042664},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.1576661467552185}],"mesh":[],"locations_count":1,"locations":[{"id":"pmh:oai:ojs.ijrcct.org:article/1035","doi":null,"is_oa":false,"landing_page_url":"http://ijrcct.org/index.php/ojs/article/view/1035","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"IJRCCT; Vol 4, No 1 (2015): January; 072-076","raw_type":"Peer-reviewed Article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"},{"score":0.9853000044822693,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W1651642741","https://openalex.org/W2102384898","https://openalex.org/W2109434460","https://openalex.org/W2111311558","https://openalex.org/W2126455698","https://openalex.org/W2131992439","https://openalex.org/W2133233732","https://openalex.org/W2136700375","https://openalex.org/W2150013600","https://openalex.org/W2155291822","https://openalex.org/W2156087476","https://openalex.org/W2158420518","https://openalex.org/W2166323418","https://openalex.org/W2542937538"],"related_works":["https://openalex.org/W2788058823","https://openalex.org/W1999302015","https://openalex.org/W2183344306","https://openalex.org/W2727910643","https://openalex.org/W1598311916","https://openalex.org/W2768544036","https://openalex.org/W2763737432","https://openalex.org/W2912317640","https://openalex.org/W2800841629"],"abstract_inverted_index":{"As":[0],"the":[1,4,9,12,21,26,31,35,47,93,107,121,163],"expansion":[2],"of":[3,11,14,34,49,145],"dc":[5,64,165],"distribution":[6,36,139],"system":[7],"and":[8,28,63,86,90,99,116,167],"augment":[10],"penetration":[13],"distributed":[15,111],"generations":[16],"an":[17,70],"intelligent":[18],"transformer":[19,44],"with":[20,136,156],"capability":[22],"to":[23,83,91,113,118,133,174],"actively":[24],"supervise":[25],"power":[27,58,88],"allowing":[29,81],"for":[30,110],"easy":[32],"connection":[33],"resources":[37,112],"is":[38],"becoming":[39],"essential.":[40],"The":[41,142,159],"solid":[42],"state":[43],"(SST)":[45],"has":[46,75],"features":[48],"immediate":[50],"voltage":[51,53,140,182],"regulation,":[52],"sag":[54],"compensation,":[55],"fault":[56,94],"isolation,":[57],"factor":[59],"correction,":[60],"harmonic":[61],"isolation":[62],"output.\u00a0":[65],"Acting":[66],"very":[67],"much":[68],"like":[69],"energy":[71,77],"router,":[72],"each":[73],"SST":[74,132,143],"bidirectional":[76],"flow":[78,89],"control":[79,84,104],"potential":[80],"it":[82],"active":[85,152],"reactive":[87],"handle":[92],"currents":[95],"on":[96],"both":[97],"low-":[98],"high-voltage":[100],"sides.":[101],"Its":[102],"large":[103],"bandwidth":[105],"offers":[106],"plug-and-play":[108],"feature":[109],"speedily":[114],"recognize":[115],"respond":[117],"changes":[119],"in":[120],"system.":[122],"This":[123],"paper":[124],"proposes":[125],"a":[126,146,176],"20-kVA":[127],"cascaded":[128,147],"H-Bridge":[129],"multilevel":[130,148],"converter-based":[131],"directly":[134],"interface":[135],"7.2-kV":[137],"single-phase":[138],"level.":[141],"consists":[144],"ac/dc":[149],"rectifier,":[150],"dual":[151],"bridge":[153],"(DAB)":[154],"converters":[155],"high-frequency":[157],"transformers.":[158],"DAB":[160],"converter":[161],"regulates":[162],"400-V-low-voltage":[164],"bus":[166],"added":[168,173],"dc/ac":[169],"inverters":[170],"can":[171],"be":[172],"present":[175],"60":[177],"Hz":[178],"120/240-V":[179],"ac":[180],"residential":[181]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W1861635876","counts_by_year":[],"updated_date":"2026-11-20T13:11:24.684918","created_date":"2025-10-10T00:00:00"}
