{"id":"https://openalex.org/W183480992","doi":null,"title":"Mobile air-conditioner refrigerant evaluation. Report for April 1988-March 1989","display_name":"Mobile air-conditioner refrigerant evaluation. Report for April 1988-March 1989","publication_year":1989,"publication_date":"1989-03-01","ids":{"openalex":"https://openalex.org/W183480992","mag":"183480992"},"language":"en","primary_location":{"id":"mag:183480992","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/5520334","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5039347006","display_name":"Dale L. Harmon","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"D.L. Harmon","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046174135","display_name":"William J. Rhodes","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"W.J. Rhodes","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5029324978","display_name":"Leo Weitzman","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Leo Weitzman","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.02754175,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12017","display_name":"Recycling and Waste Management Techniques","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2311","display_name":"Waste Management and Disposal"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11320","display_name":"Atmospheric Ozone and Climate","score":0.0,"subfield":{"id":"https://openalex.org/subfields/1902","display_name":"Atmospheric Science"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/automotive-air-conditioning","display_name":"automotive air conditioning","score":0.7509999871253967},{"id":"https://openalex.org/keywords/cfc-12","display_name":"CFC-12","score":0.9900000095367432},{"id":"https://openalex.org/keywords/r22","display_name":"R22","score":0.9210000038146973},{"id":"https://openalex.org/keywords/refrigerant-leakage","display_name":"refrigerant leakage","score":0.675000011920929}],"concepts":[{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.977053701877594},{"id":"https://openalex.org/C131097465","wikidata":"https://www.wikidata.org/wiki/Q178898","display_name":"Gas compressor","level":2,"score":0.8607017993927002},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.8463237285614014},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.6100283861160278},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.46924686431884766},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.39723077416419983},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.39542895555496216},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.12607818841934204}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:183480992","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/5520334","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2283372574","https://openalex.org/W1492543817","https://openalex.org/W312428963","https://openalex.org/W4233654892","https://openalex.org/W2767088570","https://openalex.org/W3160190804","https://openalex.org/W1992338027","https://openalex.org/W948240599","https://openalex.org/W4240116777","https://openalex.org/W4241201429"],"abstract_inverted_index":{"This":[0],"paper":[1],"discusses":[2],"an":[3],"evaluation":[4],"of":[5,28,38,65,84,94],"refrigerant":[6,17,34],"from":[7],"mobile":[8],"air":[9,97],"conditioners.":[10],"The":[11,63],"data":[12],"gathered":[13],"indicate":[14],"that":[15,52],"CFC-12":[16,74],"does":[18,102],"not":[19,50,103],"degrade":[20],"significantly":[21],"with":[22,32,42],"use.":[23],"Furthermore,":[24],"while":[25,109],"small":[26],"amounts":[27],"contaminant":[29,90],"are":[30],"removed":[31],"the":[33,39,43,53,59,70,85,95,111],"during":[35],"servicing,":[36],"most":[37],"contaminants":[40],"remain":[41],"compressor":[44,54,60],"oil.":[45],"Current":[46],"servicing":[47],"practices":[48],"do":[49],"require":[51],"oil":[55],"be":[56],"changed":[57],"unless":[58],"is":[61,76],"replaced.":[62],"presence":[64],"HCFC-22":[66,89],"in":[67,80,110],"concentrations":[68],"above":[69],"specification":[71],"for":[72],"new":[73],"(0.5%)":[75],"rare;":[77],"it":[78],"occurred":[79],"less":[81],"than":[82],"1%":[83],"227":[86],"cars":[87],"tested.":[88],"quickly":[91],"leaks":[92],"out":[93],"automotive":[96],"conditioner":[98],"through":[99],"hoses":[100],"and":[101],"appear":[104],"to":[105],"cause":[106],"operational":[107],"problems":[108],"system.":[112]},"counts_by_year":[],"updated_date":"2026-09-22T06:50:58.402377","created_date":"2016-06-24T00:00:00"}
