{"id":"https://openalex.org/W182010195","doi":null,"title":"Performance Evaluation of the LABGEO PT10 Point-of-care Chemistry Analyzer","display_name":"Performance Evaluation of the LABGEO PT10 Point-of-care Chemistry Analyzer","publication_year":2013,"publication_date":"2013-12-01","ids":{"openalex":"https://openalex.org/W182010195","mag":"182010195"},"language":"en","primary_location":{"id":"mag:182010195","doi":null,"is_oa":false,"landing_page_url":"http://www.jlmqa.org/journal/download_pdf.php?spage=70&volume=35&number=2","pdf_url":null,"source":{"id":"https://openalex.org/S2764575435","display_name":"Imsang byeong'ri wa jeongdo gwanri/Journal of laboratory medicine and quality assurance","issn_l":"1225-097X","issn":["1225-097X","2288-7261","2384-2458","2950-9114","2950-9122"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["kci-registered"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Imsang byeong'ri wa jeongdo gwanri/Journal of laboratory medicine and quality assurance","raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5031941923","display_name":"Tae\u2010Dong Jeong","orcid":"https://orcid.org/0000-0002-3873-3117","observed_orcids":["https://orcid.org/0000-0002-3873-3117"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Tae\u2010Dong Jeong","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0002-3873-3117","affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5036071429","display_name":"Woochang Lee","orcid":"https://orcid.org/0000-0003-3956-6397","observed_orcids":["https://orcid.org/0000-0003-3956-6397"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Woochang Lee","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0003-3956-6397","affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5048244620","display_name":"Sail Chun","orcid":"https://orcid.org/0000-0002-5792-973X","observed_orcids":["https://orcid.org/0000-0002-5792-973X"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Sail Chun","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5110000717","display_name":"Won Ki Min","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Won Ki Min","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.6955,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.88601383,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":98},"biblio":{"volume":"35","issue":"2","first_page":"70","last_page":"80"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11314","display_name":"Clinical Laboratory Practices and Quality Control","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11314","display_name":"Clinical Laboratory Practices and Quality Control","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T12167","display_name":"Bacterial Identification and Susceptibility Testing","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2726","display_name":"Microbiology (medical)"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11460","display_name":"Analytical Methods in Pharmaceuticals","score":0.0,"subfield":{"id":"https://openalex.org/subfields/1602","display_name":"Analytical Chemistry"},"field":{"id":"https://openalex.org/fields/16","display_name":"Chemistry"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/point-of-care-testing","display_name":"point-of-care testing","score":0.9819999933242798},{"id":"https://openalex.org/keywords/analytical-performance","display_name":"analytical performance","score":0.5839999914169312},{"id":"https://openalex.org/keywords/precision","display_name":"precision","score":0.777999997138977},{"id":"https://openalex.org/keywords/linearity","display_name":"linearity","score":0.8740000128746033},{"id":"https://openalex.org/keywords/method-comparison","display_name":"method comparison","score":0.7049999833106995},{"id":"https://openalex.org/keywords/hdl-cholesterol","display_name":"HDL cholesterol","score":0.9309999942779541}],"concepts":[{"id":"https://openalex.org/C10390740","wikidata":"https://www.wikidata.org/wiki/Q2282401","display_name":"Analyte","level":2,"score":0.6998563408851624},{"id":"https://openalex.org/C158007255","wikidata":"https://www.wikidata.org/wiki/Q1055222","display_name":"Spectrum analyzer","level":2,"score":0.677322268486023},{"id":"https://openalex.org/C43617362","wikidata":"https://www.wikidata.org/wiki/Q170050","display_name":"Chromatography","level":1,"score":0.556588351726532},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.548970103263855},{"id":"https://openalex.org/C64841741","wikidata":"https://www.wikidata.org/wiki/Q491983","display_name":"Point-of-care testing","level":2,"score":0.49716928601264954},{"id":"https://openalex.org/C113196181","wikidata":"https://www.wikidata.org/wiki/Q485223","display_name":"Analytical Chemistry (journal)","level":2,"score":0.4337610602378845},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.15917134284973145},{"id":"https://openalex.org/C203014093","wikidata":"https://www.wikidata.org/wiki/Q101929","display_name":"Immunology","level":1,"score":0.1138911247253418},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.09572497010231018},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:182010195","doi":null,"is_oa":false,"landing_page_url":"http://www.jlmqa.org/journal/download_pdf.php?spage=70&volume=35&number=2","pdf_url":null,"source":{"id":"https://openalex.org/S2764575435","display_name":"Imsang byeong'ri wa jeongdo gwanri/Journal of laboratory medicine and quality assurance","issn_l":"1225-097X","issn":["1225-097X","2288-7261","2384-2458","2950-9114","2950-9122"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["kci-registered"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Imsang byeong'ri wa jeongdo gwanri/Journal of laboratory medicine and quality assurance","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.5683000087738037}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W89818456","https://openalex.org/W1507178887","https://openalex.org/W2000610385","https://openalex.org/W2035611566","https://openalex.org/W2061434077","https://openalex.org/W2099652529","https://openalex.org/W2115006318","https://openalex.org/W2138115661","https://openalex.org/W2167657120","https://openalex.org/W2402350344","https://openalex.org/W2743041357","https://openalex.org/W3143904421"],"related_works":["https://openalex.org/W2521006190","https://openalex.org/W2154901469","https://openalex.org/W2138115661","https://openalex.org/W2566689401","https://openalex.org/W2587191318","https://openalex.org/W1822822614","https://openalex.org/W7099142615","https://openalex.org/W7027353217","https://openalex.org/W2955473487","https://openalex.org/W2408605494"],"abstract_inverted_index":{"Results:":[0],"In":[1],"the":[2,17,23,29,43,47,59,126,138],"precision":[3,112],"analysis,":[4],"both":[5],"within-run":[6],"and":[7,70,88,97,113,115,134],"total-run":[8],"coefficients":[9,39],"of":[10,40,46,77,129,136],"variation":[11],"were":[12,26,72,85],"less":[13],"than":[14,92],"10%":[15],"for":[16,22,42,56],"seven":[18,24,44],"analytes.":[19],"Dose":[20],"curves":[21],"analytes":[25],"linear":[27],"in":[28,81,95],"clinically":[30],"relevant":[31],"concentration":[32],"ranges.":[33],"The":[34,75,102],"methodology":[35],"study":[36],"yielded":[37],"correlation":[38,119],"\u22650.98":[41],"comparisons":[45],"LABGEO":[48,103,139],"PT10":[49,104,140],"cartridge":[50],"tests":[51],"with":[52,109,120],"other":[53,121],"methods.":[54],"Except":[55],"HDL":[57,78],"cholesterol,":[58],"percentage":[60],"differences":[61],"between":[62],"test":[63],"results":[64],"obtained":[65],"from":[66],"whole":[67,82],"blood,":[68],"plasma,":[69],"serum,":[71],"within":[73],"\u00b110%.":[74],"concentrations":[76],"cholesterol":[79],"measured":[80,94],"blood":[83],"samples":[84],"0.9":[86],"mg/dL":[87,90],"5.6":[89],"higher":[91],"those":[93],"plasma":[96],"serum":[98],"specimens,":[99],"respectively.":[100],"Conclusions:":[101],"showed":[105],"suitable":[106],"analytical":[107],"performance":[108],"respect":[110],"to":[111],"linearity":[114],"demonstrated":[116],"a":[117],"good":[118],"automated":[122],"chemistry":[123,145],"analyzers.":[124],"With":[125],"additional":[127],"benefits":[128],"short":[130],"testing":[131],"turnaround":[132],"time":[133],"ease":[135],"use,":[137],"is":[141],"an":[142],"acceptable":[143],"POCT":[144],"analyzer.":[146],"(":[147],"J":[148],"Lab":[149],"Med":[150],"Qual":[151],"Assur":[152],"2013;35:70-80)":[153]},"counts_by_year":[{"year":2018,"cited_by_count":1},{"year":2016,"cited_by_count":4}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2016-06-24T00:00:00"}