{"id":"https://openalex.org/W167836737","doi":null,"title":"A vision for reducing boiler tube failures","display_name":"A vision for reducing boiler tube failures","alternate_titles":[],"publication_year":1992,"publication_date":"1992-03-01","ids":{"openalex":"https://openalex.org/W167836737","mag":"167836737"},"language":"en","primary_location":{"id":"mag:167836737","doi":null,"is_oa":false,"landing_page_url":"https://www.osti.gov/scitech/biblio/5428734","pdf_url":null,"source":{"id":"https://openalex.org/S4210230886","display_name":"Power engineering","issn_l":"2156-1451","issn":["2156-1451","2378-4628"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310320584","host_organization_name":"CRC Press","host_organization_lineage":["https://openalex.org/P4310320584","https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["CRC Press","Taylor & Francis","Informa"],"type":"book series"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Power engineering","raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W167836737"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5113515350","display_name":"Barry Dooley","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"B. Dooley","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5113515350"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.0492,"has_fulltext":false,"cited_by_count":16,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.73691065,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":92},"biblio":{"volume":"96","issue":"3","first_page":"33","last_page":"37"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13213","display_name":"Mechanical Failure Analysis and Simulation","score":0.8765000104904175,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13213","display_name":"Mechanical Failure Analysis and Simulation","score":0.8765000104904175,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13856","display_name":"Advanced Power Generation Technologies","score":0.05400000140070915,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.036400001496076584,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/boiler-tube-failure","display_name":"boiler tube failure","score":0.9610000252723694},{"id":"https://openalex.org/keywords/fossil-fuel-power-plants","display_name":"fossil fuel power plants","score":0.8740000128746033},{"id":"https://openalex.org/keywords/forced-outages","display_name":"forced outages","score":0.6859999895095825},{"id":"https://openalex.org/keywords/equipment-availability","display_name":"equipment availability","score":0.6209999918937683},{"id":"https://openalex.org/keywords/root-cause-analysis","display_name":"root cause analysis","score":0.8960000276565552},{"id":"https://openalex.org/keywords/utility-reliability","display_name":"utility reliability","score":0.4970000088214874}],"concepts":[{"id":"https://openalex.org/C2780013297","wikidata":"https://www.wikidata.org/wiki/Q19596153","display_name":"Boiler (water heating)","level":2,"score":0.7906265258789062},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.559042751789093},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5309502482414246},{"id":"https://openalex.org/C84945661","wikidata":"https://www.wikidata.org/wiki/Q7366567","display_name":"Root cause","level":2,"score":0.5132064819335938},{"id":"https://openalex.org/C77595967","wikidata":"https://www.wikidata.org/wiki/Q3151013","display_name":"Forensic engineering","level":1,"score":0.44821494817733765},{"id":"https://openalex.org/C4311470","wikidata":"https://www.wikidata.org/wiki/Q159719","display_name":"Power station","level":2,"score":0.4162610173225403},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.35694363713264465},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.29570621252059937},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.15964260697364807}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:167836737","doi":null,"is_oa":false,"landing_page_url":"https://www.osti.gov/scitech/biblio/5428734","pdf_url":null,"source":{"id":"https://openalex.org/S4210230886","display_name":"Power engineering","issn_l":"2156-1451","issn":["2156-1451","2378-4628"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310320584","host_organization_name":"CRC Press","host_organization_lineage":["https://openalex.org/P4310320584","https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["CRC Press","Taylor & Francis","Informa"],"type":"book series"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Power engineering","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W1497963212","https://openalex.org/W54026285","https://openalex.org/W18508885","https://openalex.org/W1599974260","https://openalex.org/W39710883","https://openalex.org/W2352953262","https://openalex.org/W157925551","https://openalex.org/W57655160","https://openalex.org/W2024360210","https://openalex.org/W3169835575"],"abstract_inverted_index":{"This":[0],"paper":[1],"reports":[2],"that":[3,43,61,69,104],"the":[4,13,24,40,78,85,94,105,133],"boiler":[5,87],"tube":[6,115],"failure":[7,116],"(BTF)":[8],"problem":[9,17],"still":[10],"ranks":[11],"as":[12],"number":[14],"one":[15],"equipment":[16],"in":[18,33,36,84,102,128],"fossil":[19],"power":[20],"plants.":[21],"According":[22],"to":[23,108,113,119,132],"North":[25,37],"American":[26],"Electric":[27],"Reliability":[28],"Council,":[29],"BTF":[30,50,124],"has":[31,59],"been":[32,47],"this":[34],"position":[35],"America":[38],"for":[39],"28":[41],"years":[42],"reliability":[44],"statistics":[45],"have":[46],"kept.":[48],"Currently":[49],"represents":[51],"about":[52],"3-4%":[53],"of":[54,65,71,97],"lost":[55],"availability.":[56],"Previous":[57],"analysis":[58],"indicated":[60],"a":[62,121,129,144],"disturbing":[63],"feature":[64],"these":[66],"failures":[67],"is":[68],"most":[70],"them":[72],"are":[73],"repeats.":[74],"They":[75],"occur":[76],"on":[77],"same":[79,81,86],"tube,":[80],"material,":[82],"or":[83],"section":[88],"over":[89,91,143],"and":[90,147],"again.":[92],"Assessing":[93],"multifunctional":[95],"nature":[96],"BTF,":[98],"it":[99],"became":[100],"apparent":[101],"1985":[103],"only":[106],"way":[107],"prevent":[109],"forced":[110],"outages":[111],"due":[112],"repeat":[114],"problems":[117],"was":[118],"implement":[120],"formalized,":[122],"company-wide":[123],"prevention":[125],"program.":[126],"Thus,":[127],"parallel":[130],"effort":[131],"root":[134],"cause":[135],"determinations,":[136],"16":[137],"utilities":[138],"demonstrated":[139],"such":[140],"an":[141],"approach":[142],"four-year":[145],"period":[146],"achieved":[148],"remarkable":[149],"availability":[150],"improvements.":[151]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W167836737","counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
