{"id":"https://openalex.org/W1601378183","doi":null,"title":"R32 As a Solution for Energy Conservation and Low Emission","display_name":"R32 As a Solution for Energy Conservation and Low Emission","alternate_titles":[],"publication_year":2000,"publication_date":"2000-01-01","ids":{"openalex":"https://openalex.org/W1601378183","mag":"1601378183"},"language":"en","primary_location":{"id":"pmh:oai:docs.lib.purdue.edu:iracc-1508","doi":null,"is_oa":false,"landing_page_url":"https://docs.lib.purdue.edu/iracc/509","pdf_url":null,"source":{"id":"https://openalex.org/S4377196310","display_name":"Purdue e-Pubs (Purdue University System)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801333002","host_organization_name":"Purdue University System","host_organization_lineage":["https://openalex.org/I2801333002"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"International Refrigeration and Air Conditioning Conference","raw_type":"text"},"parent_works":[],"lineage":["https://openalex.org/W1601378183"],"child_works_count":0,"pull_notice_works":[],"type":"conference-abstract","is_traditional":false,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5111468472","display_name":"R. Yajima","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"R. Yajima","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077691409","display_name":"Koji Kita","type":null,"orcid":"https://orcid.org/0000-0002-3753-8125","observed_orcids":["https://orcid.org/0000-0002-3753-8125"]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Koji Kita","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5074074524","display_name":"Shigeharu Taira","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Shigeharu Taira","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5017127808","display_name":"N. Domyo","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"N. Domyo","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":15,"reviewed_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11774","display_name":"Adsorption and Cooling Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/r32-refrigerant","display_name":"R32 refrigerant","score":0.8939999938011169},{"id":"https://openalex.org/keywords/low-gwp-refrigerants","display_name":"low-GWP refrigerants","score":0.6919999718666077},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"air conditioning","score":0.7979999780654907},{"id":"https://openalex.org/keywords/variable-speed-compressor","display_name":"variable speed compressor","score":0.7009999752044678},{"id":"https://openalex.org/keywords/coefficient-of-performance","display_name":"coefficient of performance","score":0.8849999904632568},{"id":"https://openalex.org/keywords/total-equivalent-warming-impact","display_name":"total equivalent warming impact","score":0.7360000014305115},{"id":"https://openalex.org/keywords/global-warming-potential","display_name":"global warming potential","score":0.7419999837875366},{"id":"https://openalex.org/keywords/refrigerant-charge-reduction","display_name":"refrigerant charge reduction","score":0.828000009059906},{"id":"https://openalex.org/keywords/heat-transfer-tubes","display_name":"heat transfer tubes","score":0.6890000104904175},{"id":"https://openalex.org/keywords/flammable-refrigerants","display_name":"flammable refrigerants","score":0.8360000252723694},{"id":"https://openalex.org/keywords/energy-conservation","display_name":"energy conservation","score":0.6159999966621399},{"id":"https://openalex.org/keywords/low-emissions","display_name":"low emissions","score":0.6940000057220459}],"concepts":[{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.9554675817489624},{"id":"https://openalex.org/C31892906","wikidata":"https://www.wikidata.org/wiki/Q5457310","display_name":"Flammable liquid","level":2,"score":0.7818514108657837},{"id":"https://openalex.org/C131097465","wikidata":"https://www.wikidata.org/wiki/Q178898","display_name":"Gas compressor","level":2,"score":0.7149220108985901},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.6105684041976929},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.5422152280807495},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5392353534698486},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.5220829844474792},{"id":"https://openalex.org/C187949908","wikidata":"https://www.wikidata.org/wiki/Q2044954","display_name":"Air source heat pumps","level":4,"score":0.4670765697956085},{"id":"https://openalex.org/C2776588112","wikidata":"https://www.wikidata.org/wiki/Q6451709","display_name":"Variable-frequency drive","level":3,"score":0.4513664245605469},{"id":"https://openalex.org/C164915370","wikidata":"https://www.wikidata.org/wiki/Q5167494","display_name":"Cooling capacity","level":2,"score":0.4286462962627411},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3440949022769928},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.28109312057495117},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.25879770517349243},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.23477551341056824},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:docs.lib.purdue.edu:iracc-1508","doi":null,"is_oa":false,"landing_page_url":"https://docs.lib.purdue.edu/iracc/509","pdf_url":null,"source":{"id":"https://openalex.org/S4377196310","display_name":"Purdue e-Pubs (Purdue University System)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801333002","host_organization_name":"Purdue University System","host_organization_lineage":["https://openalex.org/I2801333002"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"International Refrigeration and Air Conditioning Conference","raw_type":"text"},{"id":"mag:1601378183","doi":null,"is_oa":false,"landing_page_url":"https://docs.lib.purdue.edu/cgi/viewcontent.cgi?article=1508&context=iracc","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Climate action","score":0.821399986743927,"id":"https://metadata.un.org/sdg/13"},{"display_name":"Affordable and clean energy","score":0.5690000057220459,"id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W3035542895","https://openalex.org/W2581350295","https://openalex.org/W3028320124","https://openalex.org/W7024424057","https://openalex.org/W3016311061","https://openalex.org/W2258987328","https://openalex.org/W4375935338","https://openalex.org/W7214492864","https://openalex.org/W1526820533","https://openalex.org/W2560399164"],"abstract_inverted_index":{"We":[0,31],"selected":[1],"the":[2,13,24,59,72,78,103,109,136,166,170,194],"low":[3,95,188],"GWP":[4],"refrigerant":[5,10,110,196],"R32,":[6],"as":[7],"a":[8,19,38,42,48,94,127,130],"promising":[9],"candidate":[11],"in":[12,140,148,158,185],"air":[14],"conditioning":[15],"field,":[16],"which":[17],"has":[18],"potential":[20],"of":[21,37,61,67,117,152,160,165,176],"economically":[22],"satisfying":[23],"requirements":[25],"for":[26,123,173],"safety":[27],"and":[28,35,98,108,154,187],"environmental":[29],"protection.":[30],"investigated":[32],"its":[33,90,99,143,183],"performance":[34,186],"TEWI":[36,144],"16kW":[39],"prototype":[40],"with":[41,150],"variable":[43],"speed":[44,83],"compressor":[45,82],"driven":[46],"by":[47,51,81,115,146],"motor":[49],"controlled":[50],"DC":[52],"inverter.":[53],"The":[54,85],"test":[55],"analysis":[56,86],"shows":[57,88],"that":[58,66,89,151],"COP":[60,92,101],"R32":[62,131,161],"is":[63,133,179],"higher":[64],"than":[65],"R410A":[68,153],"not":[69],"only":[70],"under":[71,77,102,181],"rated":[73],"capacity":[74,79],"but":[75],"even":[76],"reduced":[80,114],"control.":[84],"also":[87],"heating":[91],"at":[93],"ambient":[96],"temperature":[97],"cooling":[100],"overload":[104],"condition":[105],"are":[106],"superior":[107],"charge":[111],"can":[112],"be":[113],"adoption":[116],"smaller":[118],"diameter":[119],"heat":[120,124],"transfer":[121],"tubes":[122],"exchangers.":[125],"As":[126],"result,":[128],"if":[129],"system":[132],"operated":[134],"during":[135],"specified":[137],"seasonal":[138],"period":[139],"Tokyo":[141],"area,":[142],"drops":[145],"18%":[147],"comparison":[149],"direct":[155],"impact":[156,189],"portion":[157],"case":[159],"decreases":[162],"to":[163],"7%":[164],"total":[167],"impact.":[168],"Since":[169],"international":[171],"standard":[172],"safe":[174],"use":[175],"flammable":[177],"refrigerants":[178],"currently":[180],"drafting,":[182],"superiority":[184],"on":[190],"warming":[191],"may":[192],"enhance":[193],"future":[195],"change.":[197]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W1601378183","counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2020,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2012,"cited_by_count":3}],"updated_date":"2026-11-25T09:40:18.809321","created_date":"2016-06-24T00:00:00"}
