{"id":"https://openalex.org/W1592890274","doi":"https://doi.org/10.1061/jsdeag.0004721","title":"Tuned Mass Dampers for Buildings","display_name":"Tuned Mass Dampers for Buildings","alternate_titles":[],"publication_year":1977,"publication_date":"1977-09-01","ids":{"openalex":"https://openalex.org/W1592890274","doi":"https://doi.org/10.1061/jsdeag.0004721","mag":"1592890274"},"language":"en","primary_location":{"id":"doi:10.1061/jsdeag.0004721","doi":"https://doi.org/10.1061/jsdeag.0004721","is_oa":false,"landing_page_url":"https://doi.org/10.1061/jsdeag.0004721","pdf_url":null,"source":{"id":"https://openalex.org/S2764514966","display_name":"Journal of the Structural Division","issn_l":"0044-8001","issn":["0044-8001","2690-3377"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of the Structural Division","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W1592890274"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5108485151","display_name":"Robert J. McNamara","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Robert J. McNamara","raw_affiliation_strings":["Principal, Gillum-Colaco Consulting Struct. Engrs., Cambridge, Mass"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Principal, Gillum-Colaco Consulting Struct. Engrs., Cambridge, Mass","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5108485151"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":9.1789,"has_fulltext":false,"cited_by_count":352,"citation_normalized_percentile":{"value":0.96088985,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":98,"max":100},"biblio":{"volume":"103","issue":"9","first_page":"1785","last_page":"1798"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10690","display_name":"Vibration Control and Rheological Fluids","score":0.9496999979019165,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10690","display_name":"Vibration Control and Rheological Fluids","score":0.9496999979019165,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13852","display_name":"Seismic and Structural Analysis of Tall Buildings","score":0.03830000013113022,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12487","display_name":"Structural Engineering and Vibration Analysis","score":0.0017999999690800905,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/tuned-mass-damper","display_name":"tuned mass damper","score":0.9869999885559082},{"id":"https://openalex.org/keywords/high-rise-buildings","display_name":"high-rise buildings","score":0.9890000224113464},{"id":"https://openalex.org/keywords/structural-vibration-control","display_name":"structural vibration control","score":0.6899999976158142},{"id":"https://openalex.org/keywords/wind-induced-vibration","display_name":"wind-induced vibration","score":0.6589999794960022},{"id":"https://openalex.org/keywords/response-reduction","display_name":"response reduction","score":0.75},{"id":"https://openalex.org/keywords/single-degree-of-freedom-system","display_name":"single-degree-of-freedom systems","score":0.9259999990463257},{"id":"https://openalex.org/keywords/damper-design-parameters","display_name":"damper design parameters","score":0.9229999780654907},{"id":"https://openalex.org/keywords/wind-tunnel-testing","display_name":"wind tunnel testing","score":0.7459999918937683}],"concepts":[{"id":"https://openalex.org/C140096630","wikidata":"https://www.wikidata.org/wiki/Q3423628","display_name":"Damper","level":2,"score":0.7603975534439087},{"id":"https://openalex.org/C19856469","wikidata":"https://www.wikidata.org/wiki/Q1891986","display_name":"Tuned mass damper","level":3,"score":0.7407833337783813},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.7098848819732666},{"id":"https://openalex.org/C111335779","wikidata":"https://www.wikidata.org/wiki/Q3454686","display_name":"Reduction (mathematics)","level":2,"score":0.5355638861656189},{"id":"https://openalex.org/C197115733","wikidata":"https://www.wikidata.org/wiki/Q1003136","display_name":"Forcing (mathematics)","level":2,"score":0.521856427192688},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4688856303691864},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.22120195627212524},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.06831306219100952},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.06087774038314819}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1061/jsdeag.0004721","doi":"https://doi.org/10.1061/jsdeag.0004721","is_oa":false,"landing_page_url":"https://doi.org/10.1061/jsdeag.0004721","pdf_url":null,"source":{"id":"https://openalex.org/S2764514966","display_name":"Journal of the Structural Division","issn_l":"0044-8001","issn":["0044-8001","2690-3377"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of the Structural Division","raw_type":"journal-article"},{"id":"mag:3169421527","doi":null,"is_oa":false,"landing_page_url":"https://jglobal.jst.go.jp/detail?JGLOBAL_ID=201002076951878005","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2075962436","https://openalex.org/W2014637831","https://openalex.org/W3100829890","https://openalex.org/W2230225591","https://openalex.org/W4255795406","https://openalex.org/W2048991339","https://openalex.org/W1529748439","https://openalex.org/W2621833461","https://openalex.org/W3049160619","https://openalex.org/W1561503470"],"abstract_inverted_index":{"Tuned":[0],"mass":[1],"dampers":[2],"attached":[3],"to":[4,31],"single":[5],"degree-of-freedom":[6],"systems":[7],"representing":[8],"tall":[9],"buildings":[10],"are":[11,15,29,40],"studied.":[12],"System":[13],"equations":[14],"formulated":[16],"and":[17,42],"solved":[18],"for":[19],"various":[20],"input":[21],"forcing":[22],"functions.":[23],"Design":[24],"parameters":[25],"of":[26,46],"the":[27,33],"damper":[28,49],"varied":[30],"study":[32],"response":[34],"reduction.":[35],"Experimental":[36],"wind":[37],"tunnel":[38],"results":[39],"presented,":[41],"a":[43,47],"practical":[44],"application":[45],"large-scale":[48],"is":[50],"illustrated.":[51]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W1592890274","counts_by_year":[{"year":2026,"cited_by_count":5},{"year":2025,"cited_by_count":15},{"year":2024,"cited_by_count":28},{"year":2023,"cited_by_count":15},{"year":2022,"cited_by_count":23},{"year":2021,"cited_by_count":12},{"year":2020,"cited_by_count":19},{"year":2019,"cited_by_count":23},{"year":2018,"cited_by_count":16},{"year":2017,"cited_by_count":16},{"year":2016,"cited_by_count":9},{"year":2015,"cited_by_count":13},{"year":2014,"cited_by_count":13},{"year":2013,"cited_by_count":8},{"year":2012,"cited_by_count":8}],"updated_date":"2026-11-20T13:11:24.684918","created_date":"2016-06-24T00:00:00"}
