{"id":"https://openalex.org/W1584060897","doi":"https://doi.org/10.1002/j.1551-8833.1993.tb06025.x","title":"Integrating Hydraulic Modeling and SCADA Systems for System Planning and Control","display_name":"Integrating Hydraulic Modeling and SCADA Systems for System Planning and Control","alternate_titles":[],"publication_year":1993,"publication_date":"1993-07-01","ids":{"openalex":"https://openalex.org/W1584060897","doi":"https://doi.org/10.1002/j.1551-8833.1993.tb06025.x","mag":"1584060897"},"language":"en","primary_location":{"id":"doi:10.1002/j.1551-8833.1993.tb06025.x","doi":"https://doi.org/10.1002/j.1551-8833.1993.tb06025.x","is_oa":false,"landing_page_url":"https://doi.org/10.1002/j.1551-8833.1993.tb06025.x","pdf_url":null,"source":{"id":"https://openalex.org/S24940445","display_name":"American Water Works Association","issn_l":"0003-150X","issn":["0003-150X","1551-8833","2164-4535"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","norway-1","poland-40","russia-white-list-3"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal AWWA","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W1584060897"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5083494005","display_name":"Andreas M. Schulte","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Andreas M. Schulte","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5008989776","display_name":"Arthur P. Malm","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Arthur P. Malm","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":3050,"currency":"USD","value_usd":3050},"apc_paid":null,"fwci":3.8186,"has_fulltext":false,"cited_by_count":12,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.89896461,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":93},"biblio":{"volume":"85","issue":"7","first_page":"62","last_page":"66"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11220","display_name":"Water Systems and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11220","display_name":"Water Systems and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13344","display_name":"Industrial Automation and Control Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10969","display_name":"Water resources management and optimization","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2312","display_name":"Water Science and Technology"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hydraulic-modeling","display_name":"hydraulic modeling","score":0.6570000052452087},{"id":"https://openalex.org/keywords/scada-systems","display_name":"SCADA systems","score":0.8389999866485596},{"id":"https://openalex.org/keywords/water-distribution-networks","display_name":"water distribution systems","score":0.8479999899864197},{"id":"https://openalex.org/keywords/operator-training","display_name":"operator training","score":0.7080000042915344},{"id":"https://openalex.org/keywords/emergency-response-simulation","display_name":"emergency response simulation","score":0.7720000147819519},{"id":"https://openalex.org/keywords/isolation-valves","display_name":"isolation valves","score":0.7210000157356262},{"id":"https://openalex.org/keywords/system-planning","display_name":"system planning","score":0.4970000088214874}],"concepts":[{"id":"https://openalex.org/C113863187","wikidata":"https://www.wikidata.org/wiki/Q17498","display_name":"SCADA","level":2,"score":0.9652203321456909},{"id":"https://openalex.org/C2779697362","wikidata":"https://www.wikidata.org/wiki/Q390516","display_name":"Control room","level":2,"score":0.5055356025695801},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.4992492198944092},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.4978032112121582},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.439573734998703},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.43765637278556824},{"id":"https://openalex.org/C92991967","wikidata":"https://www.wikidata.org/wiki/Q7644329","display_name":"Supervisory control","level":3,"score":0.4239833950996399},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.42264053225517273},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4090186357498169},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.36806803941726685},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.367068886756897},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.34947073459625244},{"id":"https://openalex.org/C147176958","wikidata":"https://www.wikidata.org/wiki/Q77590","display_name":"Civil engineering","level":1,"score":0.14689254760742188},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1002/j.1551-8833.1993.tb06025.x","doi":"https://doi.org/10.1002/j.1551-8833.1993.tb06025.x","is_oa":false,"landing_page_url":"https://doi.org/10.1002/j.1551-8833.1993.tb06025.x","pdf_url":null,"source":{"id":"https://openalex.org/S24940445","display_name":"American Water Works Association","issn_l":"0003-150X","issn":["0003-150X","1551-8833","2164-4535"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","norway-1","poland-40","russia-white-list-3"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal AWWA","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2132487062","https://openalex.org/W2332044979","https://openalex.org/W3045316704","https://openalex.org/W20728147","https://openalex.org/W2184701973","https://openalex.org/W2112268711","https://openalex.org/W6922350835","https://openalex.org/W2072613921","https://openalex.org/W2510303900","https://openalex.org/W2127822242"],"abstract_inverted_index":{"The":[0,30,78,127],"DuPage":[1],"Water":[2],"Commission":[3],"(DWC)":[4],"of":[5,61,89,109,115,148],"Elmhurst,":[6],"Ill.,":[7],"has":[8,80,124],"built":[9],"a":[10,74,135,146],"new":[11],"water":[12],"distribution":[13],"network":[14],"and":[15,24,36,47,93,140],"is":[16],"monitoring":[17],"it":[18],"using":[19],"an":[20,70,131],"integrated":[21],"supervisory":[22],"control":[23],"data":[25,116],"acquisition":[26],"(SCADA)":[27],"simulator":[28,39,119],"(ISS).":[29],"ISS":[31,79],"integrates":[32],"DWC's":[33],"SCADA":[34,122],"system":[35,42,76,85,105,123,147],"its":[37],"hydraulic":[38,63],"to":[40,50,52,68,120,133],"confirm":[41],"design,":[43],"develop":[44],"operational":[45,71],"scenarios,":[46],"train":[48],"operators":[49,156],"respond":[51],"emergencies.":[53],"Operations":[54],"personnel":[55],"have":[56],"already":[57],"verified":[58],"the":[59,62,90,104,107,118,121,154,167],"accuracy":[60],"simulator,":[64],"which":[65,170],"enabled":[66],"them":[67],"resolve":[69],"problem":[72],"involving":[73],"low\u2010pressure":[75],"response.":[77],"been":[81,125],"demonstrated":[82],"for":[83,87,94,138],"initial":[84],"studies,":[86],"verification":[88],"transfer":[91],"mechanism,":[92],"actual":[95],"storage":[96],"management":[97],"studies":[98],"during":[99],"unexpected":[100],"drought":[101],"strains":[102],"on":[103],"in":[106,166,173],"summer":[108],"1992.":[110,175],"Emergency":[111],"training":[112,128],"through":[113],"return":[114],"from":[117],"delayed.":[126],"will":[129],"enable":[130],"operator":[132],"simulate":[134],"main":[136],"break,":[137],"example,":[139],"practice":[141],"alternative":[142],"responses":[143],"by":[144],"manipulating":[145],"remotely":[149],"controlled":[150],"isolation":[151],"valves.":[152],"Using":[153],"ISS,":[155],"can":[157],"become":[158],"familiar":[159],"with":[160],"unusual":[161],"conditions":[162],"before":[163],"they":[164],"occur":[165],"real":[168],"system,":[169],"began":[171],"operation":[172],"January":[174]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W1584060897","counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2016,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
