{"id":"https://openalex.org/W1556972869","doi":"https://doi.org/10.1049/cp.2009.0854","title":"Failure analysis of medium voltage capacitor banks: the Egyptian experience","display_name":"Failure analysis of medium voltage capacitor banks: the Egyptian experience","alternate_titles":[],"publication_year":2009,"publication_date":"2009-01-01","ids":{"openalex":"https://openalex.org/W1556972869","doi":"https://doi.org/10.1049/cp.2009.0854","mag":"1556972869"},"language":"en","primary_location":{"id":"doi:10.1049/cp.2009.0854","doi":"https://doi.org/10.1049/cp.2009.0854","is_oa":false,"landing_page_url":"https://doi.org/10.1049/cp.2009.0854","pdf_url":null,"source":{"id":"https://openalex.org/S4306512867","display_name":"IET Conference Publications","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Conference Publications","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W1556972869"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"M.A. El-Hadidy","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"M.A. El-Hadidy","raw_affiliation_strings":["Tech. Consultant, Egyptian Electricity Transmission company, Egypt"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Tech. Consultant, Egyptian Electricity Transmission company, Egypt","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5074187780","display_name":"Dalal Hussein Helmi","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"D.H. Helmi","raw_affiliation_strings":["Studies and Research Dept., Egyptian Electricity Transmission company, Egypt"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Studies and Research Dept., Egyptian Electricity Transmission company, Egypt","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":5,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"581","last_page":"581"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.7768999934196472,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.7768999934196472,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13213","display_name":"Mechanical Failure Analysis and Simulation","score":0.1088000014424324,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.023000000044703484,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/capacitor-bank","display_name":"capacitor bank","score":0.7879999876022339},{"id":"https://openalex.org/keywords/failure-modes","display_name":"failure modes","score":0.8809999823570251},{"id":"https://openalex.org/keywords/transmission-networks","display_name":"transmission networks","score":0.6309999823570251},{"id":"https://openalex.org/keywords/power-quality","display_name":"power quality","score":0.6029999852180481},{"id":"https://openalex.org/keywords/utility-reliability","display_name":"utility reliability","score":0.7039999961853027}],"concepts":[{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.833191990852356},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.7166925072669983},{"id":"https://openalex.org/C3018344627","wikidata":"https://www.wikidata.org/wiki/Q1925224","display_name":"Failure mechanism","level":2,"score":0.548984944820404},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.526086688041687},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5079177021980286},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.492170512676239},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.4915390908718109},{"id":"https://openalex.org/C184773241","wikidata":"https://www.wikidata.org/wiki/Q387400","display_name":"Mains electricity","level":3,"score":0.46249938011169434},{"id":"https://openalex.org/C28719098","wikidata":"https://www.wikidata.org/wiki/Q44946","display_name":"Point (geometry)","level":2,"score":0.4542945921421051},{"id":"https://openalex.org/C35196352","wikidata":"https://www.wikidata.org/wiki/Q1532649","display_name":"Decoupling capacitor","level":4,"score":0.4415624737739563},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.4315081536769867},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.4122452139854431},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.41192543506622314},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.39415496587753296},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3471330404281616},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.34409379959106445},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.10321807861328125},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.07405811548233032},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1049/cp.2009.0854","doi":"https://doi.org/10.1049/cp.2009.0854","is_oa":false,"landing_page_url":"https://doi.org/10.1049/cp.2009.0854","pdf_url":null,"source":{"id":"https://openalex.org/S4306512867","display_name":"IET Conference Publications","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Conference Publications","raw_type":"proceedings-article"},{"id":"mag:3150857330","doi":null,"is_oa":false,"landing_page_url":"http://yadda.icm.edu.pl/yadda/element/bwmeta1.element.ieee-000005255842","pdf_url":null,"source":{"id":"https://openalex.org/S4306498970","display_name":"International Conference and Exhibition on Electricity Distribution (CIRED)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"CIRED 2009 - The 20th International Conference and Exhibition on Electricity Distribution","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":1.0},{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.571399986743927}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1554988792","https://openalex.org/W2069652288","https://openalex.org/W2091706030","https://openalex.org/W2160837215"],"related_works":["https://openalex.org/W2387772971","https://openalex.org/W2591092497","https://openalex.org/W2376396195","https://openalex.org/W2160837215","https://openalex.org/W1554988792","https://openalex.org/W2488375487","https://openalex.org/W1989837334","https://openalex.org/W2351358967","https://openalex.org/W1978863594","https://openalex.org/W2350264552"],"abstract_inverted_index":{"This":[0],"paper":[1],"describes":[2],"the":[3,7,12,16,24,29,33,37,51,73,81,88,94,106,117],"failure":[4,60,62],"modes":[5],"in":[6,11,36,45,84,116],"capacitor":[8,25,43,98,110],"banks":[9,26,99],"installed":[10,27],"Egyptian":[13,38,118],"Network":[14],"over":[15],"past":[17],"years.":[18],"The":[19,91],"study":[20,95],"has":[21],"focused":[22],"on":[23,96],"at":[28],"MV":[30],"side":[31],"of":[32,42,53,76,93,100,109],"HV":[34],"substations":[35,46],"Transmission":[39],"Network.":[40],"Failures":[41],"units/banks":[44],"can":[47],"be":[48],"detrimental":[49],"to":[50,56,86],"supply":[52],"reliable":[54],"power":[55],"consumers.":[57],"Failure":[58],"analysis,":[59],"mechanism,":[61],"origin":[63],"and":[64,112],"physical":[65],"damage":[66],"causes":[67,108],"were":[68],"studied,":[69],"not":[70],"only":[71],"from":[72,80],"manufacturing":[74],"point":[75],"view,":[77],"but":[78],"also":[79],"utility":[82,89],"prospective":[83],"order":[85],"enhance":[87],"reliability.":[90],"results":[92],"457":[97],"about":[101],"2383":[102],"MVARs":[103],"capacity":[104],"revealed":[105],"main":[107],"accidents,":[111],"sum":[113],"up":[114],"experiences":[115],"Electricity":[119],"Utility.":[120]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W1556972869","counts_by_year":[{"year":2019,"cited_by_count":3},{"year":2017,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2026-11-14T11:04:58.165337","created_date":"2016-06-24T00:00:00"}