{"id":"https://openalex.org/W1553511","doi":null,"title":"Super Good Cents Heat Loss Reference : Manufactured Homes : Heat Loss Assumptions and Calculations, Heat Loss Coefficient Tables.","display_name":"Super Good Cents Heat Loss Reference : Manufactured Homes : Heat Loss Assumptions and Calculations, Heat Loss Coefficient Tables.","publication_year":1991,"publication_date":"1991-02-01","ids":{"openalex":"https://openalex.org/W1553511","mag":"1553511"},"language":"en","primary_location":{"id":"mag:1553511","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/5818210-super-good-cents-heat-loss-reference-manufactured-homes-heat-loss-assumptions-calculations-heat-loss-coefficient-tables","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"B.W. Davis","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"B.W. Davis","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5085607046","display_name":"David Baylon","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"David Baylon","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5002855728","display_name":"Mike Kennedy","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Mike Kennedy","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.00038241,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.9775000214576721,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.9775000214576721,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.019200000911951065,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13116","display_name":"Heat Transfer and Numerical Methods","score":0.0005000000237487257,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/manufactured-housing","display_name":"manufactured housing","score":0.9819999933242798},{"id":"https://openalex.org/keywords/heat-loss","display_name":"heat loss","score":0.8989999890327454},{"id":"https://openalex.org/keywords/thermal-transmittance","display_name":"thermal transmittance","score":0.8270000219345093},{"id":"https://openalex.org/keywords/thermal-performance","display_name":"thermal performance","score":0.6959999799728394},{"id":"https://openalex.org/keywords/wall-insulation","display_name":"wall insulation","score":0.9430000185966492},{"id":"https://openalex.org/keywords/window-insulation","display_name":"window insulation","score":0.7360000014305115},{"id":"https://openalex.org/keywords/thermal-conductivity","display_name":"thermal conductivity","score":0.597000002861023},{"id":"https://openalex.org/keywords/construction-practices","display_name":"construction practices","score":0.597000002861023},{"id":"https://openalex.org/keywords/energy-efficiency","display_name":"energy efficiency","score":0.5070000290870667}],"concepts":[{"id":"https://openalex.org/C206145494","wikidata":"https://www.wikidata.org/wiki/Q4654236","display_name":"ASHRAE 90.1","level":2,"score":0.7867505550384521},{"id":"https://openalex.org/C125209513","wikidata":"https://www.wikidata.org/wiki/Q4037520","display_name":"Doors","level":2,"score":0.7166587710380554},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.6995906233787537},{"id":"https://openalex.org/C20556612","wikidata":"https://www.wikidata.org/wiki/Q4469374","display_name":"Volume (thermodynamics)","level":2,"score":0.49271586537361145},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.41287297010421753},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.38824716210365295},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.37658238410949707},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3746432065963745},{"id":"https://openalex.org/C199639397","wikidata":"https://www.wikidata.org/wiki/Q1788588","display_name":"Engineering drawing","level":1,"score":0.3423582911491394},{"id":"https://openalex.org/C77595967","wikidata":"https://www.wikidata.org/wiki/Q3151013","display_name":"Forensic engineering","level":1,"score":0.3412874639034271},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.20534586906433105},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.1906464397907257},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.10488945245742798},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:1553511","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/5818210-super-good-cents-heat-loss-reference-manufactured-homes-heat-loss-assumptions-calculations-heat-loss-coefficient-tables","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[{"id":"https://openalex.org/G2779574474","display_name":null,"funder_award_id":"Y01-HC-50011-00","funder_id":"https://openalex.org/F4320337338","funder_display_name":"National Heart, Lung, and Blood Institute"}],"funders":[{"id":"https://openalex.org/F4320337338","display_name":"National Heart, Lung, and Blood Institute","ror":"https://ror.org/012pb6c26"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W4249253898","https://openalex.org/W91309712","https://openalex.org/W1502708739","https://openalex.org/W1591245625","https://openalex.org/W2907056493","https://openalex.org/W1722878398","https://openalex.org/W1797993874","https://openalex.org/W4388152845","https://openalex.org/W2773338667","https://openalex.org/W1510277451"],"abstract_inverted_index":{"This":[0,72,115],"manual":[1],"is":[2,74],"intended":[3],"to":[4,45,67,91,100],"assist":[5],"builders":[6],"of":[7,15,79],"manufactured":[8,54,62,121],"homes":[9],"in":[10,24,50,65],"assessing":[11],"the":[12,25,37,46,51,110],"thermal":[13,93],"performance":[14],"structural":[16],"components":[17,33,82],"(floor,":[18],"ceilings,":[19],"walls,":[20],"and":[21,86,107,125],"windows)":[22],"used":[23,90],"Super":[26],"Good":[27],"Cents":[28],"Program.":[29],"U-factors":[30,108],"for":[31,96,109],"these":[32],"are":[34,83],"calculated":[35],"using":[36],"ASHRAE":[38],"(1989)":[39],"parallel":[40],"heat":[41],"loss":[42],"method":[43],"adapted":[44],"construction":[47,70],"practices":[48],"found":[49],"Pacific":[52],"Northwest":[53,61],"home":[55,63,122],"industry.":[56],"Ecotope":[57],"staff":[58],"visited":[59],"several":[60],"plants":[64],"1990":[66],"determine":[68],"current":[69],"practices.":[71],"volume":[73,116],"organized":[75],"component-by-component,":[76],"with":[77],"explanations":[78],"how":[80],"different":[81],"put":[84],"together":[85],"which":[87],"methods":[88],"were":[89],"find":[92],"conductivities":[94],"(U-factors)":[95],"components.":[97],"The":[98],"appendices":[99],"this":[101],"report":[102],"contain":[103],"representative":[104],"component":[105],"drawings":[106],"many":[111],"possible":[112],"insulation":[113],"strategies.":[114],"does":[117],"not":[118],"discuss":[119],"two":[120],"components:":[123],"skylights":[124],"doors.":[126],"9":[127],"refs.,":[128],"6":[129],"figs.,":[130],"2":[131],"tabs.":[132]},"counts_by_year":[],"updated_date":"2026-10-14T16:39:01.820549","created_date":"2016-06-24T00:00:00"}