{"id":"https://openalex.org/W1552425552","doi":"https://doi.org/10.1109/icdcm.2015.7152018","title":"Alleviating power quality issues when integrating PV into built areas: Design and control of DC microgrids","display_name":"Alleviating power quality issues when integrating PV into built areas: Design and control of DC microgrids","publication_year":2015,"publication_date":"2015-06-01","ids":{"openalex":"https://openalex.org/W1552425552","doi":"https://doi.org/10.1109/icdcm.2015.7152018","mag":"1552425552"},"language":"en","primary_location":{"id":"doi:10.1109/icdcm.2015.7152018","doi":"https://doi.org/10.1109/icdcm.2015.7152018","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icdcm.2015.7152018","pdf_url":null,"source":{"id":"https://openalex.org/S4306422624","display_name":"IEEE International Conference on DC Microgrids","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE First International Conference on DC Microgrids (ICDCM)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Vincenzo Musolino","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I135218257","display_name":"Swiss Center for Electronics and Microtechnology (Switzerland)","ror":"https://ror.org/05nrrsx06","country_code":"CH","type":"company","lineage":["https://openalex.org/I135218257"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Vincenzo Musolino","raw_affiliation_strings":["PV-center, CSEM, Neuch\u00e2tel, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"PV-center, CSEM, Neuch\u00e2tel, Switzerland","institution_ids":["https://openalex.org/I135218257"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5019261066","display_name":"Pierre\u2010Jean Alet","orcid":"https://orcid.org/0000-0003-0604-9043","observed_orcids":["https://orcid.org/0000-0003-0604-9043"]},"institutions":[{"id":"https://openalex.org/I135218257","display_name":"Swiss Center for Electronics and Microtechnology (Switzerland)","ror":"https://ror.org/05nrrsx06","country_code":"CH","type":"company","lineage":["https://openalex.org/I135218257"]},{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["CH","IT"],"is_corresponding":false,"raw_author_name":"Pierre-Jean Alet","raw_affiliation_strings":["Department of Electrical Engineering, Politecnico di Milano, Milan, Italy","PV-center, CSEM, Neuch\u00e2tel, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Politecnico di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]},{"raw_affiliation_string":"PV-center, CSEM, Neuch\u00e2tel, Switzerland","institution_ids":["https://openalex.org/I135218257"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5038738471","display_name":"Laure\u2010Emmanuelle Perret\u2010Aebi","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I135218257","display_name":"Swiss Center for Electronics and Microtechnology (Switzerland)","ror":"https://ror.org/05nrrsx06","country_code":"CH","type":"company","lineage":["https://openalex.org/I135218257"]},{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["CH","IT"],"is_corresponding":false,"raw_author_name":"Laure-Emmanuelle Perret-Aebi","raw_affiliation_strings":["Department of Electrical Engineering, Politecnico di Milano, Milan, Italy","PV-center, CSEM, Neuch\u00e2tel, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Politecnico di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]},{"raw_affiliation_string":"PV-center, CSEM, Neuch\u00e2tel, Switzerland","institution_ids":["https://openalex.org/I135218257"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030049999","display_name":"Christophe Ballif","orcid":"https://orcid.org/0000-0001-8989-0545","observed_orcids":["https://orcid.org/0000-0001-8989-0545"]},"institutions":[{"id":"https://openalex.org/I135218257","display_name":"Swiss Center for Electronics and Microtechnology (Switzerland)","ror":"https://ror.org/05nrrsx06","country_code":"CH","type":"company","lineage":["https://openalex.org/I135218257"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Christophe Ballif","raw_affiliation_strings":["PV-center, CSEM, Neuch\u00e2tel, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"PV-center, CSEM, Neuch\u00e2tel, Switzerland","institution_ids":["https://openalex.org/I135218257"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5069509112","display_name":"Luigi Piegari","orcid":"https://orcid.org/0000-0003-3776-7486","observed_orcids":["https://orcid.org/0000-0003-3776-7486"]},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Luigi Piegari","raw_affiliation_strings":["Department of Electrical Engineering, Politecnico di Milano, Milan, Italy","Department of Electrical Engineering, Politecnico di Milano, Milan, Italy#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Politecnico di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]},{"raw_affiliation_string":"Department of Electrical Engineering, Politecnico di Milano, Milan, Italy#TAB#","institution_ids":["https://openalex.org/I93860229"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.9337,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.66123726,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":96},"biblio":{"volume":"29","issue":null,"first_page":"102","last_page":"107"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9901999831199646,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9901999831199646,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.003599999938160181,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.0012000000569969416,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/power-quality","display_name":"power quality","score":0.8939999938011169},{"id":"https://openalex.org/keywords/photovoltaic-integration","display_name":"photovoltaic integration","score":0.9300000071525574},{"id":"https://openalex.org/keywords/dc-microgrid","display_name":"DC microgrid","score":0.9739999771118164},{"id":"https://openalex.org/keywords/voltage-fluctuation","display_name":"voltage fluctuation","score":0.5260000228881836},{"id":"https://openalex.org/keywords/power-ramp","display_name":"power ramp","score":0.7979999780654907},{"id":"https://openalex.org/keywords/ramp-rate-control","display_name":"ramp rate control","score":0.8640000224113464},{"id":"https://openalex.org/keywords/voltage-stability","display_name":"voltage stability","score":0.7250000238418579},{"id":"https://openalex.org/keywords/energy-storage-state-of-charge","display_name":"energy storage state of charge","score":0.7870000004768372},{"id":"https://openalex.org/keywords/low-voltage-feeders","display_name":"low-voltage feeders","score":0.777999997138977},{"id":"https://openalex.org/keywords/communication-free-control","display_name":"communication-free control","score":0.5440000295639038}],"concepts":[{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.587518572807312},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.5597697496414185},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5147323608398438},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5099166631698608},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.4961867928504944},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.46675682067871094},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4518369138240814},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.4492088258266449},{"id":"https://openalex.org/C2779665505","wikidata":"https://www.wikidata.org/wiki/Q1780079","display_name":"Power quality","level":3,"score":0.42693910002708435},{"id":"https://openalex.org/C195697387","wikidata":"https://www.wikidata.org/wiki/Q5608561","display_name":"Grid-connected photovoltaic power system","level":5,"score":0.41942036151885986},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.41029542684555054},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3950842618942261},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.3626887798309326},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3425142168998718},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.11717426776885986},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/icdcm.2015.7152018","doi":"https://doi.org/10.1109/icdcm.2015.7152018","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icdcm.2015.7152018","pdf_url":null,"source":{"id":"https://openalex.org/S4306422624","display_name":"IEEE International Conference on DC Microgrids","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE First International Conference on DC Microgrids (ICDCM)","raw_type":"proceedings-article"},{"id":"pmh:oai:re.public.polimi.it:11311/980976","doi":null,"is_oa":false,"landing_page_url":"http://hdl.handle.net/11311/980976","pdf_url":null,"source":{"id":"https://openalex.org/S4306400312","display_name":"Virtual Community of Pathological Anatomy (University of Castilla La Mancha)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I79189158","host_organization_name":"University of Castilla-La Mancha","host_organization_lineage":["https://openalex.org/I79189158"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"},{"score":0.7207000255584717,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"},{"id":"https://openalex.org/F4320338290","display_name":"National Renewable Energy Laboratory","ror":"https://ror.org/036266993"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W1568212236","https://openalex.org/W1909787217","https://openalex.org/W1989698061","https://openalex.org/W2076606363","https://openalex.org/W2098711962","https://openalex.org/W2137246289","https://openalex.org/W2144073697","https://openalex.org/W2146531934","https://openalex.org/W2154729209","https://openalex.org/W2530626634","https://openalex.org/W2538669251","https://openalex.org/W2731050121","https://openalex.org/W2771682931","https://openalex.org/W2907455153","https://openalex.org/W4207054975"],"related_works":["https://openalex.org/W2742541632","https://openalex.org/W2735375982","https://openalex.org/W3170853094","https://openalex.org/W4383069030","https://openalex.org/W2802671002","https://openalex.org/W2541441675","https://openalex.org/W4296474494","https://openalex.org/W2113444835","https://openalex.org/W3004411662","https://openalex.org/W2765551171"],"abstract_inverted_index":{"Increasing":[0],"penetration":[1],"of":[2,15,18,25,31,56,92,113,115,128,140],"PV":[3],"sources":[4],"in":[5,34],"LV":[6],"grids":[7],"is":[8,71,132],"introducing":[9],"new":[10],"challenges":[11],"to":[12,27,60,73,83,119],"the":[13,28,32,54,61,75,86,93,97,111,120,124,126,129],"quality":[14],"voltage.":[16],"Variability":[17],"solar":[19,141],"radiation":[20],"can":[21],"cause":[22],"power":[23,30,50,94],"ramps":[24],"up":[26],"nominal":[29],"plant":[33],"one":[35],"second,":[36],"which":[37],"directly":[38],"induces":[39],"voltage":[40,101],"fluctuations":[41],"on":[42,49,103],"distribution":[43],"feeders.":[44],"To":[45],"mitigate":[46],"this":[47],"impact":[48],"quality,":[51],"we":[52],"investigate":[53],"introduction":[55],"dc":[57,105,121],"micro-grids":[58],"interfaced":[59],"ac":[62,98,107],"grid":[63],"through":[64],"four-quadrant":[65],"inverter.":[66],"The":[67],"introduced":[68],"control":[69,91],"strategy":[70,131],"able":[72],"manage":[74],"entire":[76],"system":[77],"without":[78],"any":[79],"communication":[80],"layer":[81],"and":[82,106,143],"ensure":[84],"at":[85],"same":[87],"time:":[88],"i)":[89],"ramp-rate":[90],"exchanged":[95],"with":[96,134],"grid;":[99],"ii)":[100],"stability":[102],"both":[104],"grids;":[108],"iii)":[109],"maintaining":[110],"state":[112],"charge":[114],"storage":[116],"devices":[117],"connected":[118],"grid.":[122],"In":[123],"paper":[125],"effectiveness":[127],"proposed":[130],"shown":[133],"numerical":[135],"simulations":[136],"considering":[137],"real":[138],"profiles":[139],"irradiation":[142],"load":[144],"power.":[145]},"counts_by_year":[{"year":2020,"cited_by_count":1},{"year":2017,"cited_by_count":2}],"updated_date":"2026-10-30T12:39:25.321706","created_date":"2016-06-24T00:00:00"}