{"id":"https://openalex.org/W1528596702","doi":"https://doi.org/10.1080/10789669.2011.564259","title":"Methodology for determining the optimal operating strategies for a chilled-water-storage system\u2014Part II: Project application","display_name":"Methodology for determining the optimal operating strategies for a chilled-water-storage system\u2014Part II: Project application","publication_year":2011,"publication_date":"2011-10-01","ids":{"openalex":"https://openalex.org/W1528596702","doi":"https://doi.org/10.1080/10789669.2011.564259","mag":"1528596702"},"language":"en","primary_location":{"id":"doi:10.1080/10789669.2011.564259","doi":"https://doi.org/10.1080/10789669.2011.564259","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1080/10789669.2011.564259","pdf_url":null,"source":{"id":"https://openalex.org/S2764534234","display_name":"Science and Technology for the Built Environment","issn_l":"1078-9669","issn":["1078-9669","1938-5587","2374-4731","2374-474X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"HVAC&amp;R Research","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101994004","display_name":"Zhiqin Zhang","orcid":"https://orcid.org/0000-0002-7850-4503","observed_orcids":["https://orcid.org/0000-0002-7850-4503"]},"institutions":[{"id":"https://openalex.org/I173268674","display_name":"Texas A&M University System","ror":"https://ror.org/0034eay46","country_code":"US","type":"education","lineage":["https://openalex.org/I173268674"]},{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Zhiqin Zhang","raw_affiliation_strings":["a Department of Mechanical Engineering , Texas A&M University , College Station, TX, 77943, USA","b Energy Systems Laboratory , Texas A&M University , 3581 TAMU, 214 Wisenbaker Engineering Research Center, Bizzel Street, College Station, TX, 77943-3581, USA","Department of Mechanical Engineering , Texas A&M University , College Station, TX, 77943, USA","Energy Systems Laboratory , Texas A&M University , 3581 TAMU, 214 Wisenbaker Engineering Research Center, Bizzel Street, College Station, TX, 77943-3581, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"a Department of Mechanical Engineering , Texas A&M University , College Station, TX, 77943, USA","institution_ids":["https://openalex.org/I91045830"]},{"raw_affiliation_string":"b Energy Systems Laboratory , Texas A&M University , 3581 TAMU, 214 Wisenbaker Engineering Research Center, Bizzel Street, College Station, TX, 77943-3581, USA","institution_ids":["https://openalex.org/I173268674","https://openalex.org/I91045830"]},{"raw_affiliation_string":"Department of Mechanical Engineering , Texas A&M University , College Station, TX, 77943, USA","institution_ids":["https://openalex.org/I91045830"]},{"raw_affiliation_string":"Energy Systems Laboratory , Texas A&M University , 3581 TAMU, 214 Wisenbaker Engineering Research Center, Bizzel Street, College Station, TX, 77943-3581, USA","institution_ids":["https://openalex.org/I173268674","https://openalex.org/I91045830"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065324167","display_name":"W. D. Turner","orcid":"https://orcid.org/0000-0001-7901-4795","observed_orcids":["https://orcid.org/0000-0001-7901-4795"]},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"William D. Turner","raw_affiliation_strings":["a Department of Mechanical Engineering , Texas A&M University , College Station, TX, 77943, USA","Department of Mechanical Engineering , Texas A&M University , College Station, TX, 77943, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"a Department of Mechanical Engineering , Texas A&M University , College Station, TX, 77943, USA","institution_ids":["https://openalex.org/I91045830"]},{"raw_affiliation_string":"Department of Mechanical Engineering , Texas A&M University , College Station, TX, 77943, USA","institution_ids":["https://openalex.org/I91045830"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100435669","display_name":"Qiang Chen","orcid":"https://orcid.org/0000-0002-2585-0234","observed_orcids":["https://orcid.org/0000-0002-2585-0234"]},"institutions":[{"id":"https://openalex.org/I173268674","display_name":"Texas A&M University System","ror":"https://ror.org/0034eay46","country_code":"US","type":"education","lineage":["https://openalex.org/I173268674"]},{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Qiang Chen","raw_affiliation_strings":["b Energy Systems Laboratory , Texas A&M University , 3581 TAMU, 214 Wisenbaker Engineering Research Center, Bizzel Street, College Station, TX, 77943-3581, USA","Energy Systems Laboratory , Texas A&M University , 3581 TAMU, 214 Wisenbaker Engineering Research Center, Bizzel Street, College Station, TX, 77943-3581, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"b Energy Systems Laboratory , Texas A&M University , 3581 TAMU, 214 Wisenbaker Engineering Research Center, Bizzel Street, College Station, TX, 77943-3581, USA","institution_ids":["https://openalex.org/I173268674","https://openalex.org/I91045830"]},{"raw_affiliation_string":"Energy Systems Laboratory , Texas A&M University , 3581 TAMU, 214 Wisenbaker Engineering Research Center, Bizzel Street, College Station, TX, 77943-3581, USA","institution_ids":["https://openalex.org/I173268674","https://openalex.org/I91045830"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5060652607","display_name":"Chen Xu","orcid":"https://orcid.org/0000-0002-5399-5297","observed_orcids":["https://orcid.org/0000-0002-5399-5297"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Chen Xu","raw_affiliation_strings":["c \rVisionBEE\r, Austin, TX, \rUSA","\rVisionBEE\r, Austin, TX, \rUSA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"c \rVisionBEE\r, Austin, TX, \rUSA","institution_ids":[]},{"raw_affiliation_string":"\rVisionBEE\r, Austin, TX, \rUSA","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101729653","display_name":"Song Deng","orcid":"https://orcid.org/0000-0002-5609-7847","observed_orcids":["https://orcid.org/0000-0002-5609-7847"]},"institutions":[{"id":"https://openalex.org/I173268674","display_name":"Texas A&M University System","ror":"https://ror.org/0034eay46","country_code":"US","type":"education","lineage":["https://openalex.org/I173268674"]},{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Song Deng","raw_affiliation_strings":["b Energy Systems Laboratory , Texas A&M University , 3581 TAMU, 214 Wisenbaker Engineering Research Center, Bizzel Street, College Station, TX, 77943-3581, USA","Energy Systems Laboratory , Texas A&M University , 3581 TAMU, 214 Wisenbaker Engineering Research Center, Bizzel Street, College Station, TX, 77943-3581, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"b Energy Systems Laboratory , Texas A&M University , 3581 TAMU, 214 Wisenbaker Engineering Research Center, Bizzel Street, College Station, TX, 77943-3581, USA","institution_ids":["https://openalex.org/I173268674","https://openalex.org/I91045830"]},{"raw_affiliation_string":"Energy Systems Laboratory , Texas A&M University , 3581 TAMU, 214 Wisenbaker Engineering Research Center, Bizzel Street, College Station, TX, 77943-3581, USA","institution_ids":["https://openalex.org/I173268674","https://openalex.org/I91045830"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.7928,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.79182443,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":"17","issue":"5","first_page":"752","last_page":"770"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.8515999913215637,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.8515999913215637,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.09610000252723694,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10938","display_name":"Phase Change Materials Research","score":0.025599999353289604,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/chilled-water-storage","display_name":"chilled water storage","score":0.9470000267028809},{"id":"https://openalex.org/keywords/thermal-energy-storage","display_name":"thermal energy storage","score":0.9750000238418579},{"id":"https://openalex.org/keywords/time-of-use-electricity-rates","display_name":"time-of-use electricity rates","score":0.8569999933242798},{"id":"https://openalex.org/keywords/optimal-operating-strategy","display_name":"optimal operating strategy","score":0.843999981880188},{"id":"https://openalex.org/keywords/energy-conservation","display_name":"energy conservation","score":0.5099999904632568},{"id":"https://openalex.org/keywords/advanced-control-systems","display_name":"advanced control systems","score":0.5759999752044678},{"id":"https://openalex.org/keywords/hourly-simulation","display_name":"hourly simulation","score":0.4440000057220459}],"concepts":[{"id":"https://openalex.org/C123516432","wikidata":"https://www.wikidata.org/wiki/Q572309","display_name":"Chilled water","level":3,"score":0.8922576904296875},{"id":"https://openalex.org/C4638862","wikidata":"https://www.wikidata.org/wiki/Q1501558","display_name":"Chiller","level":2,"score":0.8665202856063843},{"id":"https://openalex.org/C2778547687","wikidata":"https://www.wikidata.org/wiki/Q193886","display_name":"Cooling tower","level":3,"score":0.8040386438369751},{"id":"https://openalex.org/C21339974","wikidata":"https://www.wikidata.org/wiki/Q178413","display_name":"Gallon (US)","level":2,"score":0.6899053454399109},{"id":"https://openalex.org/C182254935","wikidata":"https://www.wikidata.org/wiki/Q1722733","display_name":"Water chiller","level":4,"score":0.5570006370544434},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5348962545394897},{"id":"https://openalex.org/C24463637","wikidata":"https://www.wikidata.org/wiki/Q5099037","display_name":"Chiller boiler system","level":5,"score":0.5020191669464111},{"id":"https://openalex.org/C183287310","wikidata":"https://www.wikidata.org/wiki/Q2142963","display_name":"Thermal energy storage","level":2,"score":0.468778520822525},{"id":"https://openalex.org/C7694927","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooling","level":2,"score":0.45663881301879883},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.4496031403541565},{"id":"https://openalex.org/C2781099182","wikidata":"https://www.wikidata.org/wiki/Q24963825","display_name":"Cooling load","level":3,"score":0.44629085063934326},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.3970873951911926},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3724595010280609},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.2105354368686676},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.16699743270874023},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.11246570944786072},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C131097465","wikidata":"https://www.wikidata.org/wiki/Q178898","display_name":"Gas compressor","level":2,"score":0.0},{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1080/10789669.2011.564259","doi":"https://doi.org/10.1080/10789669.2011.564259","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1080/10789669.2011.564259","pdf_url":null,"source":{"id":"https://openalex.org/S2764534234","display_name":"Science and Technology for the Built Environment","issn_l":"1078-9669","issn":["1078-9669","1938-5587","2374-4731","2374-474X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"HVAC&amp;R Research","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.9853000044822693},{"display_name":"Climate action","id":"https://metadata.un.org/sdg/13","score":0.821399986743927}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W90807020"],"related_works":["https://openalex.org/W90807020","https://openalex.org/W1531320545","https://openalex.org/W1983056857","https://openalex.org/W2187465457","https://openalex.org/W2077049609","https://openalex.org/W1963798325","https://openalex.org/W82228145","https://openalex.org/W4293879928","https://openalex.org/W2184387322","https://openalex.org/W6990929950"],"abstract_inverted_index":{"A":[0],"new":[1],"methodology":[2,60],"for":[3,9,120],"determining":[4],"the":[5,34,73,77,103,115,121,132,152,179,187,203,219,224],"optimal":[6,74,212],"operating":[7],"strategies":[8,214],"a":[10,14,27,42,47],"chilled-water-storage":[11],"system":[12,45,70,88,225],"under":[13],"time-of-use":[15],"electricity":[16],"rate":[17,107],"structure":[18,108],"is":[19,30,40,41,65,109,128,139],"introduced":[20,31,110],"in":[21,62,68,218],"Part":[22,25],"I.":[23],"In":[24],"II,":[26],"practical":[28],"project":[29],"to":[32,71,113,150,155,176,190,206],"illustrate":[33],"application":[35],"of":[36,76,87,210],"this":[37,63,69],"methodology.":[38],"It":[39],"large-scale":[43],"chilled-water":[44],"with":[46,202],"5.4":[48],"million":[49],"gallon":[50],"water":[51,166],"storage":[52,80],"tank":[53],"and":[54,82,91,97,111,117,123,135,148,160,169,194,226],"an":[55,136],"advanced":[56],"control":[57,213],"system.":[58],"The":[59,85,105,163,182],"proposed":[61],"dissertation":[64],"successfully":[66],"applied":[67],"search":[72],"operations":[75],"thermal":[78],"energy":[79],"(TES)":[81],"chiller":[83,164],"plant.":[84],"profiles":[86],"cooling":[89,170],"load":[90],"weather":[92],"conditions":[93],"between":[94],"March":[95],"2007":[96],"February":[98],"2008":[99],"are":[100,146,174],"selected":[101],"as":[102],"baseline.":[104],"utility":[106],"analyzed":[112],"define":[114],"off-peak":[116],"on-peak":[118],"periods":[119],"summer":[122],"winter":[124],"months.":[125],"Each":[126],"component":[127],"modeled":[129],"based":[130],"on":[131,223],"trended":[133],"data,":[134],"hourly":[137],"simulation":[138,183],"performed":[140,222],"month":[141],"by":[142],"month.":[143],"Six":[144],"scenarios":[145],"designed":[147],"simulated":[149],"study":[151],"savings":[153,188,204],"due":[154,189,205],"TES":[156,158,191,207],"application,":[157],"optimization,":[159],"plant":[161,180,195],"optimization.":[162],"chilled":[165],"leaving":[167],"temperature":[168,173],"tower":[171],"approach":[172],"optimized":[175],"further":[177],"improve":[178],"performance.":[181],"results":[184],"show":[185],"that":[186],"operation":[192],"optimization":[193,196,221],"could":[197],"be":[198],"very":[199],"significant":[200,228],"compared":[201],"application.":[208],"Many":[209],"these":[211],"have":[215],"been":[216],"implemented":[217],"actual":[220],"achieved":[227],"savings.":[229]},"counts_by_year":[{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2026-11-10T11:39:43.021295","created_date":"2016-06-24T00:00:00"}
