{"id":"https://openalex.org/W1521222641","doi":"https://doi.org/10.1109/iembs.1998.746945","title":"Micro motor based new type of endoscope","display_name":"Micro motor based new type of endoscope","publication_year":2002,"publication_date":"2002-11-27","ids":{"openalex":"https://openalex.org/W1521222641","doi":"https://doi.org/10.1109/iembs.1998.746945","mag":"1521222641"},"language":"en","primary_location":{"id":"doi:10.1109/iembs.1998.746945","doi":"https://doi.org/10.1109/iembs.1998.746945","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.1998.746945","pdf_url":null,"source":{"id":"https://openalex.org/S4363608786","display_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","issn_l":"2375-7477","issn":["2375-7477"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["doyens","jufo-1","ki-jl-1","medline","russia-white-list-3"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101928232","display_name":"Liang Gao","orcid":"https://orcid.org/0000-0002-7683-8059","observed_orcids":["https://orcid.org/0000-0002-7683-8059"]},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"L.M. Gao","raw_affiliation_strings":["Department of Instrumentation Engineering, Shanghai Jiaotong University, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Instrumentation Engineering, Shanghai Jiaotong University, China","institution_ids":["https://openalex.org/I183067930"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037255496","display_name":"Y. Chen","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Y. Chen","raw_affiliation_strings":["Department of Instrumentation Engineering, Shanghai Jiaotong University, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Instrumentation Engineering, Shanghai Jiaotong University, China","institution_ids":["https://openalex.org/I183067930"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5042024250","display_name":"Li-Wei Lin","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"L.M. Lin","raw_affiliation_strings":["Department of Instrumentation Engineering, Shanghai Jiaotong University, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Instrumentation Engineering, Shanghai Jiaotong University, China","institution_ids":["https://openalex.org/I183067930"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5044625107","display_name":"Guo-Jhih Yan","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"G.Z. Yan","raw_affiliation_strings":["Department of Instrumentation Engineering, Shanghai Jiaotong University, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Instrumentation Engineering, Shanghai Jiaotong University, China","institution_ids":["https://openalex.org/I183067930"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I183067930"],"apc_list":null,"apc_paid":null,"fwci":2.3987,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.87932844,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":"4","issue":null,"first_page":"1822","last_page":"1825"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11486","display_name":"Micro and Nano Robotics","score":0.6503999829292297,"subfield":{"id":"https://openalex.org/subfields/3104","display_name":"Condensed Matter Physics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11486","display_name":"Micro and Nano Robotics","score":0.6503999829292297,"subfield":{"id":"https://openalex.org/subfields/3104","display_name":"Condensed Matter Physics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10369","display_name":"Advanced MEMS and NEMS Technologies","score":0.2393999993801117,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10868","display_name":"Soft Robotics and Applications","score":0.011900000274181366,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/micromotors","display_name":"micromotors","score":0.777999997138977},{"id":"https://openalex.org/keywords/medical-endoscopes","display_name":"medical endoscopes","score":0.828000009059906},{"id":"https://openalex.org/keywords/microelectromechanical-systems","display_name":"microelectromechanical systems","score":0.9039999842643738},{"id":"https://openalex.org/keywords/minimally-invasive-surgery","display_name":"minimally invasive surgery","score":0.9710000157356262}],"concepts":[{"id":"https://openalex.org/C2776820786","wikidata":"https://www.wikidata.org/wiki/Q580725","display_name":"Endoscope","level":2,"score":0.8785918354988098},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5215620398521423},{"id":"https://openalex.org/C9652623","wikidata":"https://www.wikidata.org/wiki/Q190109","display_name":"Field (mathematics)","level":2,"score":0.5182437896728516},{"id":"https://openalex.org/C3019477240","wikidata":"https://www.wikidata.org/wiki/Q1755504","display_name":"Invasive surgery","level":2,"score":0.5077934861183167},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.4869026243686676},{"id":"https://openalex.org/C2777551076","wikidata":"https://www.wikidata.org/wiki/Q842332","display_name":"Front (military)","level":2,"score":0.48626744747161865},{"id":"https://openalex.org/C2985005502","wikidata":"https://www.wikidata.org/wiki/Q6806593","display_name":"Medical robotics","level":3,"score":0.4739765524864197},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.4652593731880188},{"id":"https://openalex.org/C2781347998","wikidata":"https://www.wikidata.org/wiki/Q1587588","display_name":"Manipulator (device)","level":3,"score":0.43896228075027466},{"id":"https://openalex.org/C2777551473","wikidata":"https://www.wikidata.org/wiki/Q2093072","display_name":"Tube (container)","level":2,"score":0.4270945191383362},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.34949588775634766},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.279562771320343},{"id":"https://openalex.org/C90509273","wikidata":"https://www.wikidata.org/wiki/Q11012","display_name":"Robot","level":2,"score":0.17893993854522705},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.17492637038230896},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.14594218134880066},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0752747654914856},{"id":"https://openalex.org/C202444582","wikidata":"https://www.wikidata.org/wiki/Q837863","display_name":"Pure mathematics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iembs.1998.746945","doi":"https://doi.org/10.1109/iembs.1998.746945","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.1998.746945","pdf_url":null,"source":{"id":"https://openalex.org/S4363608786","display_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","issn_l":"2375-7477","issn":["2375-7477"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["doyens","jufo-1","ki-jl-1","medline","russia-white-list-3"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4043000042438507,"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W1605741053","https://openalex.org/W2027862952","https://openalex.org/W2090695595","https://openalex.org/W2116013011","https://openalex.org/W2164215272","https://openalex.org/W4251463496"],"related_works":["https://openalex.org/W3139988996","https://openalex.org/W2148520949","https://openalex.org/W2125087997","https://openalex.org/W2100884402","https://openalex.org/W1736327909","https://openalex.org/W2151053513","https://openalex.org/W2113490114","https://openalex.org/W2090278413","https://openalex.org/W2005892962","https://openalex.org/W110226069"],"abstract_inverted_index":{"The":[0],"application":[1],"of":[2,10,31,39,48],"micro":[3,26],"electro":[4],"mechanical":[5],"systems":[6],"in":[7],"the":[8,36,42],"field":[9],"biomedical":[11],"engineering":[12],"is":[13],"a":[14,25,29,45],"new":[15,46],"technological":[16],"field,":[17],"which":[18],"accords":[19],"with":[20,28],"minimally":[21],"invasive":[22],"surgery.":[23],"Applying":[24],"motor,":[27],"diameter":[30],"only":[32],"2":[33],"mm,":[34],"as":[35],"driving":[37],"device":[38],"this":[40],"system,":[41],"authors":[43],"present":[44],"type":[47],"medical":[49],"endoscope":[50],"whose":[51],"diagnosing":[52],"tube":[53],"front":[54],"tip":[55],"can":[56],"work":[57],"automatically.":[58]},"counts_by_year":[{"year":2020,"cited_by_count":1},{"year":2016,"cited_by_count":1}],"updated_date":"2026-10-27T15:51:10.671819","created_date":"2016-06-24T00:00:00"}
