{"id":"https://openalex.org/W1520705609","doi":"https://doi.org/10.1109/intlec.2004.1401446","title":"Enabling fuel cells for standby power - chemical hydride fueling technology","display_name":"Enabling fuel cells for standby power - chemical hydride fueling technology","publication_year":2005,"publication_date":"2005-04-06","ids":{"openalex":"https://openalex.org/W1520705609","doi":"https://doi.org/10.1109/intlec.2004.1401446","mag":"1520705609"},"language":"en","primary_location":{"id":"doi:10.1109/intlec.2004.1401446","doi":"https://doi.org/10.1109/intlec.2004.1401446","is_oa":false,"landing_page_url":"https://doi.org/10.1109/intlec.2004.1401446","pdf_url":null,"source":{"id":"https://openalex.org/S4306420285","display_name":"International Workshop on Computational Electronics","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2004 10th International Workshop on Computational Electronics (IEEE Cat. No.04EX915)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"G.M. Smith","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"G.M. Smith","raw_affiliation_strings":["Millennium Cell, Inc., Eatontown, NJ, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Millennium Cell, Inc., Eatontown, NJ, USA","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5030694396","display_name":"Roxanne P. Spencer","orcid":"https://orcid.org/0000-0001-7238-825X","observed_orcids":["https://orcid.org/0000-0001-7238-825X"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"R.P. Spencer","raw_affiliation_strings":["Millennium Cell, Inc., Eatontown, NJ, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Millennium Cell, Inc., Eatontown, NJ, USA","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":4.203,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.91402462,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"65","last_page":"72"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10811","display_name":"Hydrogen Storage and Materials","score":0.5938000082969666,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10811","display_name":"Hydrogen Storage and Materials","score":0.5938000082969666,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10409","display_name":"Fuel Cells and Related Materials","score":0.24330000579357147,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11007","display_name":"Hybrid Renewable Energy Systems","score":0.14329999685287476,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/proton-exchange-membrane-fuel-cells","display_name":"proton exchange membrane fuel cells","score":0.9300000071525574},{"id":"https://openalex.org/keywords/standby-power","display_name":"standby power","score":0.7590000033378601},{"id":"https://openalex.org/keywords/on-demand-hydrogen-production","display_name":"on-demand hydrogen production","score":0.8809999823570251},{"id":"https://openalex.org/keywords/hydrogen-storage","display_name":"hydrogen storage","score":0.7390000224113464}],"concepts":[{"id":"https://openalex.org/C2780945871","wikidata":"https://www.wikidata.org/wiki/Q194274","display_name":"Backup","level":2,"score":0.7186341285705566},{"id":"https://openalex.org/C68044625","wikidata":"https://www.wikidata.org/wiki/Q1203442","display_name":"Hydrogen storage","level":3,"score":0.7033801078796387},{"id":"https://openalex.org/C9682599","wikidata":"https://www.wikidata.org/wiki/Q11549077","display_name":"Hydrogen fuel","level":3,"score":0.5289480686187744},{"id":"https://openalex.org/C185798385","wikidata":"https://www.wikidata.org/wiki/Q1161707","display_name":"Benchmark (surveying)","level":2,"score":0.45712631940841675},{"id":"https://openalex.org/C39380314","wikidata":"https://www.wikidata.org/wiki/Q478859","display_name":"Hydrogen economy","level":4,"score":0.43690428137779236},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4337165355682373},{"id":"https://openalex.org/C129174363","wikidata":"https://www.wikidata.org/wiki/Q5157025","display_name":"Compressed hydrogen","level":4,"score":0.4336080849170685},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.42669692635536194},{"id":"https://openalex.org/C542482507","wikidata":"https://www.wikidata.org/wiki/Q1854358","display_name":"Hydrogen technologies","level":5,"score":0.4205721616744995},{"id":"https://openalex.org/C512968161","wikidata":"https://www.wikidata.org/wiki/Q556","display_name":"Hydrogen","level":2,"score":0.3890123963356018},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3681274652481079},{"id":"https://openalex.org/C2987658370","wikidata":"https://www.wikidata.org/wiki/Q180253","display_name":"Fuel cells","level":2,"score":0.36027735471725464},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22774261236190796},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.11141055822372437},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.08067995309829712},{"id":"https://openalex.org/C42360764","wikidata":"https://www.wikidata.org/wiki/Q83588","display_name":"Chemical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C13280743","wikidata":"https://www.wikidata.org/wiki/Q131089","display_name":"Geodesy","level":1,"score":0.0},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.0},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/intlec.2004.1401446","doi":"https://doi.org/10.1109/intlec.2004.1401446","is_oa":false,"landing_page_url":"https://doi.org/10.1109/intlec.2004.1401446","pdf_url":null,"source":{"id":"https://openalex.org/S4306420285","display_name":"International Workshop on Computational Electronics","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2004 10th International Workshop on Computational Electronics (IEEE Cat. No.04EX915)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"},{"score":0.8970999717712402,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W1551902209","https://openalex.org/W1581211845","https://openalex.org/W2065931191","https://openalex.org/W2112240757","https://openalex.org/W2116285475","https://openalex.org/W2158224405","https://openalex.org/W2161728520","https://openalex.org/W2321010976","https://openalex.org/W2481735848","https://openalex.org/W2972154078","https://openalex.org/W4307770699","https://openalex.org/W6683956549"],"related_works":["https://openalex.org/W2538201418","https://openalex.org/W110645602","https://openalex.org/W4391790488","https://openalex.org/W4242017318","https://openalex.org/W2005701962","https://openalex.org/W2116285475","https://openalex.org/W169903258","https://openalex.org/W2065931191","https://openalex.org/W2533155527","https://openalex.org/W2069882456"],"abstract_inverted_index":{"Early":[0],"market":[1],"entry":[2],"versions":[3],"of":[4,45,52,92,98,121,150,156,166,220,222],"PEM":[5,46],"fuel":[6,47,54,59,204],"cells":[7,48],"and":[8,25,33,81,141,169,183,224],"their":[9],"attendant":[10],"fueling":[11],"systems":[12,55,130],"are":[13,63,131,144,197],"now":[14],"being":[15],"deployed":[16],"with":[17],"early":[18],"adopters":[19],"to":[20,41,56,76],"evaluate":[21],"system":[22,73],"performance,":[23],"suitability,":[24],"reliability":[26],"for":[27,31,180,191,202],"backup":[28],"power":[29,36],"applications":[30],"telecom":[32],"related":[34],"critical":[35],"systems.":[37],"One":[38],"important":[39],"barrier":[40],"the":[42,58,101,113,153,185,209,212],"widespread":[43],"use":[44],"will":[49,228],"be":[50],"deployment":[51],"hydrogen":[53,94,123,136,151,158],"supply":[57],"cell.":[60],"While":[61,195],"there":[62,196],"several":[64],"options":[65,201],"in":[66,105,126],"this":[67,206],"area,":[68],"as":[69,119],"yet":[70],"no":[71],"commercial":[72],"can":[74],"claim":[75],"provide":[77,229],"a":[78,230],"completely":[79],"satisfactory":[80],"cost":[82],"effective":[83],"solution.":[84,233],"Fueling":[85],"approaches":[86],"fall":[87],"into":[88],"two":[89],"categories:":[90],"storage":[91,104,120,125],"preproduced":[93],"or":[95,124],"on-demand":[96,203],"production":[97,149],"hydrogen.":[99],"In":[100],"former":[102],"category,":[103],"steel":[106],"cylinders":[107],"provided":[108],"by":[109],"merchant":[110],"suppliers":[111],"is":[112,137],"benchmark,":[114],"incumbent":[115],"technology.":[116],"Alternatives":[117],"such":[118],"cryogenic":[122],"reversible":[127],"metal":[128],"hydride":[129],"less":[132,146],"desirable.":[133],"Options":[134],"where":[135],"produced":[138],"on":[139,176,216],"site":[140],"then":[142],"stored":[143],"also":[145,173],"effective.":[147],"\"On-demand\"":[148],"has":[152],"key":[154],"advantage":[155],"reducing":[157],"inventories":[159],"which":[160],"otherwise":[161],"cause":[162],"siting":[163],"issues":[164],"because":[165],"fire":[167],"codes":[168],"workplace":[170],"standards.":[171],"It":[172],"reduces":[174],"dependence":[175],"specialized":[177],"distribution":[178],"channels":[179],"compressed":[181,192],"gasses":[182],"eliminates":[184],"large,":[186],"heavy":[187],"packaging":[188],"(cylinders)":[189],"required":[190],"gas":[193],"distribution.":[194],"relatively":[198],"few":[199],"viable":[200],"processing,":[205],"paper":[207],"makes":[208],"case":[210],"that":[211],"leading":[213],"option,":[214],"relying":[215],"rapid,":[217],"catalyzed":[218],"processing":[219],"mixtures":[221],"water":[223],"reactive":[225],"chemical":[226],"hydrides":[227],"value-added,":[231],"cost-effective":[232]},"counts_by_year":[],"updated_date":"2026-10-30T12:39:25.321706","created_date":"2016-06-24T00:00:00"}
