{"id":"https://openalex.org/W1508661932","doi":null,"title":"Detection of inter-turns short circuits in permanent magnet synchronous motors operating under transient conditions by means of the zero sequence voltage","display_name":"Detection of inter-turns short circuits in permanent magnet synchronous motors operating under transient conditions by means of the zero sequence voltage","publication_year":2011,"publication_date":"2011-09-15","ids":{"openalex":"https://openalex.org/W1508661932","mag":"1508661932"},"language":"en","primary_location":{"id":"pmh:oai:CiteSeerX.psu:10.1.1.917.9049","doi":null,"is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.917.9049","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://upcommons.upc.edu/bitstream/handle/2117/13683/DETECTION%20OF%20INTER-TURNS%201.pdf%3Bjsessionid%3D06D96AF8F930764187E431E89F5C896D?sequence%3D1","raw_type":"text"},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5111430434","display_name":"Julio-C\u00e9sar Urresty","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"J. Urresty","raw_affiliation_strings":["Motion Control and Industrial Applications Group, Universitat Polit\u00e8cnica de Catalunya, Gaia Building, Rambla Sant Nebridi., 08222 Terrassa. Catalonia. Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Motion Control and Industrial Applications Group, Universitat Polit\u00e8cnica de Catalunya, Gaia Building, Rambla Sant Nebridi., 08222 Terrassa. Catalonia. Spain","institution_ids":["https://openalex.org/I9617848"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5005977069","display_name":"Jordi\u2010Roger Riba","orcid":"https://orcid.org/0000-0001-8774-2389","observed_orcids":["https://orcid.org/0000-0001-8774-2389"]},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Jordi\u2010Roger Riba","raw_affiliation_strings":["Motion Control and Industrial Applications Group, Universitat Polit\u00e8cnica de Catalunya, Gaia Building, Rambla Sant Nebridi., 08222 Terrassa. Catalonia. Spain"],"raw_orcid":"https://orcid.org/0000-0001-8774-2389","affiliations":[{"raw_affiliation_string":"Motion Control and Industrial Applications Group, Universitat Polit\u00e8cnica de Catalunya, Gaia Building, Rambla Sant Nebridi., 08222 Terrassa. Catalonia. Spain","institution_ids":["https://openalex.org/I9617848"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5052375202","display_name":"Harold Saavedra","orcid":"https://orcid.org/0000-0001-9672-4887","observed_orcids":["https://orcid.org/0000-0001-9672-4887"]},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Harold Saavedra","raw_affiliation_strings":["Motion Control and Industrial Applications Group, Universitat Polit\u00e8cnica de Catalunya, Gaia Building, Rambla Sant Nebridi., 08222 Terrassa. Catalonia. Spain"],"raw_orcid":"https://orcid.org/0000-0001-9672-4887","affiliations":[{"raw_affiliation_string":"Motion Control and Industrial Applications Group, Universitat Polit\u00e8cnica de Catalunya, Gaia Building, Rambla Sant Nebridi., 08222 Terrassa. Catalonia. Spain","institution_ids":["https://openalex.org/I9617848"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5013476676","display_name":"Luis Romeral","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"L. Romeral","raw_affiliation_strings":["Motion Control and Industrial Applications Group, Universitat Polit\u00e8cnica de Catalunya, Gaia Building, Rambla Sant Nebridi., 08222 Terrassa. Catalonia. Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Motion Control and Industrial Applications Group, Universitat Polit\u00e8cnica de Catalunya, Gaia Building, Rambla Sant Nebridi., 08222 Terrassa. Catalonia. Spain","institution_ids":["https://openalex.org/I9617848"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I9617848"],"apc_list":null,"apc_paid":null,"fwci":2.0978,"has_fulltext":false,"cited_by_count":35,"citation_normalized_percentile":{"value":0.874965,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"9"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.975600004196167,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.975600004196167,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.01360000018030405,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.004100000020116568,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/inter-turn-short-circuit","display_name":"inter-turn short circuit","score":0.8230000138282776},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-motor","display_name":"permanent magnet synchronous motor","score":0.9359999895095825},{"id":"https://openalex.org/keywords/zero-sequence-voltage","display_name":"zero-sequence voltage","score":0.8889999985694885},{"id":"https://openalex.org/keywords/stator-winding-faults","display_name":"stator winding faults","score":0.8619999885559082},{"id":"https://openalex.org/keywords/transient-conditions","display_name":"transient conditions","score":0.8510000109672546},{"id":"https://openalex.org/keywords/hilbert-huang-transform","display_name":"Hilbert-Huang transform","score":0.9819999933242798},{"id":"https://openalex.org/keywords/online-fault-diagnosis","display_name":"real-time fault diagnosis","score":0.8489999771118164},{"id":"https://openalex.org/keywords/speed-dependence","display_name":"speed dependence","score":0.4690000116825104}],"concepts":[{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.8165598511695862},{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.8006666898727417},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6875814199447632},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5566401481628418},{"id":"https://openalex.org/C16389437","wikidata":"https://www.wikidata.org/wiki/Q11421","display_name":"Magnet","level":2,"score":0.5294175744056702},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5209785103797913},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.478874146938324},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.46940505504608154},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.4469633102416992},{"id":"https://openalex.org/C2778112365","wikidata":"https://www.wikidata.org/wiki/Q3511065","display_name":"Sequence (biology)","level":2,"score":0.43985942006111145},{"id":"https://openalex.org/C28799612","wikidata":"https://www.wikidata.org/wiki/Q685437","display_name":"Hilbert transform","level":3,"score":0.43564873933792114},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.42652571201324463},{"id":"https://openalex.org/C165296897","wikidata":"https://www.wikidata.org/wiki/Q552380","display_name":"Symmetrical components","level":4,"score":0.4250250458717346},{"id":"https://openalex.org/C71376005","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Synchronous motor","level":2,"score":0.42137160897254944},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.4112614095211029},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3302842676639557},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.32126474380493164},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.22593176364898682},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.07258221507072449},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0630040168762207},{"id":"https://openalex.org/C54355233","wikidata":"https://www.wikidata.org/wiki/Q7162","display_name":"Genetics","level":1,"score":0.0},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:CiteSeerX.psu:10.1.1.917.9049","doi":null,"is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.917.9049","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://upcommons.upc.edu/bitstream/handle/2117/13683/DETECTION%20OF%20INTER-TURNS%201.pdf%3Bjsessionid%3D06D96AF8F930764187E431E89F5C896D?sequence%3D1","raw_type":"text"},{"id":"mag:1508661932","doi":null,"is_oa":false,"landing_page_url":"https://upcommons.upc.edu/bitstream/2117/13683/1/DETECTION%20OF%20INTER-TURNS%201.pdf","pdf_url":null,"source":{"id":"https://openalex.org/S4306418342","display_name":"European Conference on Power Electronics and Applications","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"European Conference on Power Electronics and Applications","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4943999946117401,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W1985275065","https://openalex.org/W1988748745","https://openalex.org/W2107430429","https://openalex.org/W2111574368","https://openalex.org/W2112690945","https://openalex.org/W2117171612","https://openalex.org/W2125663341","https://openalex.org/W2127136782","https://openalex.org/W2139853183","https://openalex.org/W2143615450","https://openalex.org/W2155752706","https://openalex.org/W2168038179","https://openalex.org/W2169582464","https://openalex.org/W2175322757"],"related_works":["https://openalex.org/W2043899981","https://openalex.org/W2963079733","https://openalex.org/W2033802545","https://openalex.org/W2026706230","https://openalex.org/W7168355744","https://openalex.org/W3085882442","https://openalex.org/W2014535589","https://openalex.org/W4389961013","https://openalex.org/W2980032157","https://openalex.org/W7123341593"],"abstract_inverted_index":{"This":[0],"work":[1,72],"proposes":[2],"the":[3,10,36,40,63,74,77],"zero":[4],"sequence":[5],"voltage":[6],"component":[7],"(ZSVC)":[8],"of":[9,62,76,86],"stator":[11,87],"three-phase":[12],"voltages":[13],"as":[14,48],"a":[15,49],"method":[16,78],"for":[17,83],"detecting":[18],"winding":[19,88],"inter-turns":[20],"short":[21],"circuits":[22],"in":[23,70],"permanent":[24],"magnet":[25],"synchronous":[26],"motors":[27],"PMSM":[28],"operating":[29],"under":[30],"transient":[31],"conditions.":[32],"Additionally":[33],"it":[34],"proves":[35],"linear":[37],"relationship":[38],"between":[39],"ZSVC":[41,55],"and":[42],"speed,":[43],"which":[44],"is":[45,58],"effectively":[46],"used":[47],"fault":[50],"severity":[51],"index.":[52],"The":[53],"acquired":[54],"temporal":[56],"signal":[57],"processed":[59],"by":[60],"means":[61],"Hilbert-Huang":[64],"transform":[65],"(HHT).":[66],"Experimental":[67],"results":[68],"presented":[69],"this":[71],"show":[73],"advantages":[75],"to":[79],"provide":[80],"helpful":[81],"data":[82],"online":[84],"diagnosis":[85],"inter-turn":[89],"faults.":[90]},"counts_by_year":[{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":3},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":4},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":3},{"year":2015,"cited_by_count":2},{"year":2013,"cited_by_count":1},{"year":2012,"cited_by_count":4}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2016-06-24T00:00:00"}
