{"id":"https://openalex.org/W1490549544","doi":"https://doi.org/10.1109/apec.2004.1295843","title":"Loss optimizing low power 50Hz transformers intended for DC/DC standby power supplies","display_name":"Loss optimizing low power 50Hz transformers intended for DC/DC standby power supplies","alternate_titles":[],"publication_year":2004,"publication_date":"2004-06-10","ids":{"openalex":"https://openalex.org/W1490549544","doi":"https://doi.org/10.1109/apec.2004.1295843","mag":"1490549544"},"language":"en","primary_location":{"id":"doi:10.1109/apec.2004.1295843","doi":"https://doi.org/10.1109/apec.2004.1295843","is_oa":false,"landing_page_url":"https://doi.org/10.1109/apec.2004.1295843","pdf_url":null,"source":{"id":"https://openalex.org/S4210177957","display_name":"Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition","issn_l":"1048-2334","issn":["1048-2334","2470-6647"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04.","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W1490549544"],"child_works_count":0,"pull_notice_works":[],"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://orbit.dtu.dk/en/publications/d718e90a-263a-4329-a5ab-c6ff9e7d4808","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5010829950","display_name":"N. Nielsen","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I96673099","display_name":"Technical University of Denmark","ror":"https://ror.org/04qtj9h94","country_code":"DK","type":"education","lineage":["https://openalex.org/I96673099"]}],"countries":["DK"],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"N. Nielsen","raw_affiliation_strings":["Oersted DTU, Technical University of Denmark, Kongens Lyngby, Denmark","Tech. Univ. Denmark, Lyngby, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Oersted DTU, Technical University of Denmark, Kongens Lyngby, Denmark","institution_ids":["https://openalex.org/I96673099"]},{"raw_affiliation_string":"Tech. Univ. Denmark, Lyngby, Denmark","institution_ids":["https://openalex.org/I96673099"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5010829950"],"corresponding_institution_ids":["https://openalex.org/I96673099"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":2,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":"1","issue":null,"first_page":"420","last_page":"425"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9848999977111816,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9848999977111816,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11222","display_name":"Magnetic Properties and Applications","score":0.012900000438094139,"subfield":{"id":"https://openalex.org/subfields/2504","display_name":"Electronic, Optical and Magnetic Materials"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transformer-efficiency","display_name":"transformer efficiency","score":0.8899999856948853},{"id":"https://openalex.org/keywords/no-load-losses","display_name":"no-load losses","score":0.8769999742507935},{"id":"https://openalex.org/keywords/dc-dc-power-supply","display_name":"DC-DC power supply","score":0.8309999704360962},{"id":"https://openalex.org/keywords/standby-power-supply","display_name":"standby power supply","score":0.8659999966621399},{"id":"https://openalex.org/keywords/buck-converter","display_name":"buck converter","score":0.7099999785423279},{"id":"https://openalex.org/keywords/transformer-optimization","display_name":"transformer optimization","score":0.4480000138282776}],"concepts":[{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.664081335067749},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5931856632232666},{"id":"https://openalex.org/C7140552","wikidata":"https://www.wikidata.org/wiki/Q1366402","display_name":"Standby power","level":3,"score":0.5210087299346924},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.4370272159576416},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.36988258361816406},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3523998260498047},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.20874592661857605}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/apec.2004.1295843","doi":"https://doi.org/10.1109/apec.2004.1295843","is_oa":false,"landing_page_url":"https://doi.org/10.1109/apec.2004.1295843","pdf_url":null,"source":{"id":"https://openalex.org/S4210177957","display_name":"Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition","issn_l":"1048-2334","issn":["1048-2334","2470-6647"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04.","raw_type":"proceedings-article"},{"id":"pmh:oai:pure.atira.dk:publications/d718e90a-263a-4329-a5ab-c6ff9e7d4808","doi":null,"is_oa":true,"landing_page_url":"https://orbit.dtu.dk/en/publications/d718e90a-263a-4329-a5ab-c6ff9e7d4808","pdf_url":null,"source":{"id":"https://openalex.org/S4306400705","display_name":"Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I96673099","host_organization_name":"Technical University of Denmark","host_organization_lineage":["https://openalex.org/I96673099"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Nielsen , N 2004 , Loss optimizing low power 50 Hz transformers intended for AC/DC standby power supplies . in Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04. . vol. 1 , IEEE , 19th Annual IEEE Applied Power Electronics Conference and Exposition , Anaheim , California , United States , 22/02/2004 . https://doi.org/10.1109/APEC.2004.1295843","raw_type":"contributionToPeriodical"}],"best_oa_location":{"id":"pmh:oai:pure.atira.dk:publications/d718e90a-263a-4329-a5ab-c6ff9e7d4808","doi":null,"is_oa":true,"landing_page_url":"https://orbit.dtu.dk/en/publications/d718e90a-263a-4329-a5ab-c6ff9e7d4808","pdf_url":null,"source":{"id":"https://openalex.org/S4306400705","display_name":"Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I96673099","host_organization_name":"Technical University of Denmark","host_organization_lineage":["https://openalex.org/I96673099"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Nielsen , N 2004 , Loss optimizing low power 50 Hz transformers intended for AC/DC standby power supplies . in Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04. . vol. 1 , IEEE , 19th Annual IEEE Applied Power Electronics Conference and Exposition , Anaheim , California , United States , 22/02/2004 . https://doi.org/10.1109/APEC.2004.1295843","raw_type":"contributionToPeriodical"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.878000020980835,"id":"https://metadata.un.org/sdg/7"},{"display_name":"Industry, innovation and infrastructure","score":0.7207000255584717,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W1951968749","https://openalex.org/W4401358926","https://openalex.org/W2126710136","https://openalex.org/W4404552495","https://openalex.org/W4413153623","https://openalex.org/W4404317533","https://openalex.org/W2735232034","https://openalex.org/W4386589313","https://openalex.org/W4226323122","https://openalex.org/W3196190737"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"the":[3],"measured":[4,35],"efficiency":[5,36],"on":[6],"selected":[7],"low":[8,61],"power":[9,29],"conventional":[10],"50":[11],"Hz/230":[12],"V-AC":[13],"transformers.":[14],"The":[15,34,54],"small":[16],"transformers":[17],"are":[18,47],"intended":[19],"for":[20,31,39,44,49],"use":[21],"in":[22],"1":[23],"W@5":[24],"V-DC":[25],"series-":[26],"or":[27],"buck-regulated":[28],"supplies":[30],"standby":[32],"purposes.":[33],"is":[37,56],"compared":[38],"cheap":[40],"off-the-self":[41],"transformer":[42],"and":[43,60],"some":[45],"which":[46],"optimized":[48],"a":[50],"lower":[51],"no-load":[52],"loss.":[53],"optimization":[55],"done":[57],"by":[58],"simple":[59],"cost":[62],"means.":[63]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W1490549544","counts_by_year":[{"year":2014,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}