{"id":"https://openalex.org/W124109274","doi":null,"title":"The Influence of Risk Prevention Measures on the Frequency of Failure of Piping","display_name":"The Influence of Risk Prevention Measures on the Frequency of Failure of Piping","alternate_titles":[],"publication_year":2010,"publication_date":"2010-01-01","ids":{"openalex":"https://openalex.org/W124109274","mag":"124109274"},"language":"en","primary_location":{"id":"pmh:oai:www.research.unipd.it:11577/2426035","doi":null,"is_oa":false,"landing_page_url":"http://hdl.handle.net/11577/2426035","pdf_url":null,"source":{"id":"https://openalex.org/S4306402547","display_name":"Padua Research Archive (University of Padova)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I138689650","host_organization_name":"University of Padua","host_organization_lineage":["https://openalex.org/I138689650"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/article"},"parent_works":[],"lineage":["https://openalex.org/W124109274"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5081088172","display_name":"Maria Francesca Milazzo","type":null,"orcid":"https://orcid.org/0000-0001-7535-3394","observed_orcids":["https://orcid.org/0000-0001-7535-3394"]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Maria Francesca Milazzo","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5073041271","display_name":"Giuseppe Maschio","type":null,"orcid":"https://orcid.org/0000-0003-0137-2028","observed_orcids":["https://orcid.org/0000-0003-0137-2028"]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Giuseppe Maschio","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5012052158","display_name":"Giovanni Uguccioni","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"G. Uguccioni","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":4.3723,"has_fulltext":false,"cited_by_count":23,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.92740515,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":86,"max":98},"biblio":{"volume":"6","issue":"1","first_page":"19","last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.9872999787330627,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.9872999787330627,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12086","display_name":"Structural Integrity and Reliability Analysis","score":0.012199999764561653,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pipe-failure","display_name":"pipe failure","score":0.7910000085830688},{"id":"https://openalex.org/keywords/loss-of-containment","display_name":"loss of containment","score":0.7829999923706055},{"id":"https://openalex.org/keywords/risk-prevention-measures","display_name":"risk prevention measures","score":0.7919999957084656},{"id":"https://openalex.org/keywords/chemical-industry-accidents","display_name":"chemical industry accidents","score":0.6949999928474426},{"id":"https://openalex.org/keywords/causes-of-failure","display_name":"failure causes","score":0.5630000233650208},{"id":"https://openalex.org/keywords/sensitivity-analysis","display_name":"sensitivity analysis","score":0.7639999985694885},{"id":"https://openalex.org/keywords/case-studies","display_name":"case studies","score":0.4309999942779541}],"concepts":[{"id":"https://openalex.org/C2779095084","wikidata":"https://www.wikidata.org/wiki/Q3679502","display_name":"Piping","level":2,"score":0.8440381288528442},{"id":"https://openalex.org/C77595967","wikidata":"https://www.wikidata.org/wiki/Q3151013","display_name":"Forensic engineering","level":1,"score":0.4576709270477295},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.45175209641456604},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.44845741987228394},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4467308819293976},{"id":"https://openalex.org/C2982805371","wikidata":"https://www.wikidata.org/wiki/Q104493","display_name":"Risk prevention","level":2,"score":0.43531981110572815},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.365556001663208},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.12736040353775024}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:www.research.unipd.it:11577/2426035","doi":null,"is_oa":false,"landing_page_url":"http://hdl.handle.net/11577/2426035","pdf_url":null,"source":{"id":"https://openalex.org/S4306402547","display_name":"Padua Research Archive (University of Padova)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I138689650","host_organization_name":"University of Padua","host_organization_lineage":["https://openalex.org/I138689650"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/article"},{"id":"mag:124109274","doi":null,"is_oa":false,"landing_page_url":"http://www.ijpe-online.com/p2-the-influence-of-risk-prevention-measures-on-the-frequency-of-failure-of-piping.html","pdf_url":null,"source":{"id":"https://openalex.org/S2764685988","display_name":"International Journal of Performability Engineering","issn_l":"0973-1318","issn":["0973-1318"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","jufo-1","norway-1","poland-40","russia-white-list-3"],"host_organization":"https://openalex.org/P4360969307","host_organization_name":"Totem Publisher","host_organization_lineage":["https://openalex.org/P4360969307"],"host_organization_lineage_names":["Totem Publisher"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"International Journal of Performability Engineering","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1966747253","https://openalex.org/W1979904766","https://openalex.org/W2012754186","https://openalex.org/W2118723260"],"related_works":["https://openalex.org/W7066074993","https://openalex.org/W2740083708","https://openalex.org/W7036323334","https://openalex.org/W3134760961","https://openalex.org/W107769976","https://openalex.org/W2189407858","https://openalex.org/W3017997042","https://openalex.org/W2060343186","https://openalex.org/W2991470021","https://openalex.org/W2979835015"],"abstract_inverted_index":{"The":[0,75],"main":[1],"causes":[2,94,112],"of":[3,20,31,42,49,56,59,61,67,69,89,95,113,130,133],"accident":[4],"in":[5,12,44,46,73,78,115],"chemical":[6],"industry":[7],"are":[8,71],"due":[9],"to":[10,104,124],"deficiencies":[11],"the":[13,18,29,32,39,54,57,65,87,90,93,98,102,111,117,120,122,128,131,134],"corporate":[14],"structure,":[15],"this":[16,79],"means":[17],"effects":[19,58],"management":[21],"and":[22,97,127],"organizational":[23],"variables":[24],"must":[25],"be":[26],"incorporated":[27],"into":[28],"assessment":[30,41],"frequency.":[33],"This":[34],"work":[35],"focuses":[36],"attention":[37],"on":[38,64,86,110],"frequency":[40],"failure":[43,96,114],"piping,":[45,116],"particular":[47],"loss":[48],"containment.":[50],"Some":[51],"methodologies":[52],"for":[53],"quantification":[55],"measures":[60,99],"risk":[62],"prevention":[63],"frequencies":[66],"rupture":[68],"piping":[70],"available":[72],"literature.":[74],"method":[76],"presented":[77],"paper":[80,118],"is":[81],"a":[82,125],"simple":[83],"approach":[84],"based":[85],"definition":[88],"links":[91],"between":[92],"adopted":[100],"by":[101],"company":[103],"prevent":[105],"them.":[106],"After":[107],"an":[108],"overview":[109],"describes":[119],"approach,":[121],"application":[123],"case-study":[126],"study":[129],"sensitivity":[132],"method.":[135]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W124109274","counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":3},{"year":2016,"cited_by_count":3},{"year":2015,"cited_by_count":5},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":5}],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2016-06-24T00:00:00"}
