{"id":"https://openalex.org/W119430975","doi":"https://doi.org/10.5070/bs3131007622","title":"Evaluating Economizer Use In Data Centers","display_name":"Evaluating Economizer Use In Data Centers","publication_year":2009,"publication_date":"2009-10-29","ids":{"openalex":"https://openalex.org/W119430975","doi":"https://doi.org/10.5070/bs3131007622","mag":"119430975"},"language":"en","primary_location":{"id":"doi:10.5070/bs3131007622","doi":"https://doi.org/10.5070/bs3131007622","is_oa":false,"landing_page_url":"https://doi.org/10.5070/bs3131007622","pdf_url":null,"source":{"id":"https://openalex.org/S2764876583","display_name":"Berkeley Scientific Journal","issn_l":"1097-0967","issn":["1097-0967","2373-8146"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","oarl","poland-40"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Berkeley Scientific Journal","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Benjamin Chu","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Benjamin Chu","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":1,"citation_normalized_percentile":{"value":0.01575212,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"13","issue":"1","first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.6718999743461609,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.6718999743461609,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.16110000014305115,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.04500000178813934,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/economizer","display_name":"economizer","score":0.8420000076293945},{"id":"https://openalex.org/keywords/data-centers","display_name":"data centers","score":0.9580000042915344},{"id":"https://openalex.org/keywords/indoor-air-quality","display_name":"indoor air quality","score":0.8270000219345093},{"id":"https://openalex.org/keywords/particulate-matter","display_name":"particulate matter","score":0.9549999833106995},{"id":"https://openalex.org/keywords/server-reliability","display_name":"server reliability","score":0.46299999952316284},{"id":"https://openalex.org/keywords/corrosion","display_name":"corrosion","score":0.703000009059906},{"id":"https://openalex.org/keywords/energy-efficiency","display_name":"energy efficiency","score":0.531000018119812},{"id":"https://openalex.org/keywords/ashrae-standards","display_name":"ASHRAE standards","score":0.7739999890327454},{"id":"https://openalex.org/keywords/aerosol-composition","display_name":"aerosol chemical composition","score":0.7379999756813049}],"concepts":[{"id":"https://openalex.org/C41004858","wikidata":"https://www.wikidata.org/wiki/Q1389702","display_name":"Economizer","level":3,"score":0.9890493154525757},{"id":"https://openalex.org/C206145494","wikidata":"https://www.wikidata.org/wiki/Q4654236","display_name":"ASHRAE 90.1","level":2,"score":0.8501800298690796},{"id":"https://openalex.org/C4638862","wikidata":"https://www.wikidata.org/wiki/Q1501558","display_name":"Chiller","level":2,"score":0.6785337328910828},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.6269065141677856},{"id":"https://openalex.org/C126314574","wikidata":"https://www.wikidata.org/wiki/Q2364111","display_name":"Air quality index","level":2,"score":0.5689315795898438},{"id":"https://openalex.org/C49996111","wikidata":"https://www.wikidata.org/wiki/Q2277783","display_name":"Free cooling","level":3,"score":0.5301117897033691},{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.48407116532325745},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.44524189829826355},{"id":"https://openalex.org/C24245907","wikidata":"https://www.wikidata.org/wiki/Q498957","display_name":"Particulates","level":2,"score":0.41284266114234924},{"id":"https://openalex.org/C65469","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air quality","level":2,"score":0.41217175126075745},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.39910975098609924},{"id":"https://openalex.org/C87717796","wikidata":"https://www.wikidata.org/wiki/Q146326","display_name":"Environmental engineering","level":1,"score":0.3836780786514282},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.37819868326187134},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.2630710005760193},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.2406574785709381},{"id":"https://openalex.org/C7694927","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooling","level":2,"score":0.22300556302070618},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.21098849177360535},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.5070/bs3131007622","doi":"https://doi.org/10.5070/bs3131007622","is_oa":false,"landing_page_url":"https://doi.org/10.5070/bs3131007622","pdf_url":null,"source":{"id":"https://openalex.org/S2764876583","display_name":"Berkeley Scientific Journal","issn_l":"1097-0967","issn":["1097-0967","2373-8146"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","oarl","poland-40"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Berkeley Scientific Journal","raw_type":"journal-article"},{"id":"pmh:oai:escholarship.org/ark:/13030/qt9g3837v1","doi":null,"is_oa":false,"landing_page_url":"https://escholarship.org/uc/item/9g3837v1","pdf_url":null,"source":{"id":"https://openalex.org/S4306400115","display_name":"eScholarship (California Digital Library)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801248553","host_organization_name":"California Digital Library","host_organization_lineage":["https://openalex.org/I2801248553"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Berkeley Scientific Journal, vol 13, iss 1","raw_type":"article"},{"id":"pmh:qt9g3837v1","doi":null,"is_oa":false,"landing_page_url":"http://www.escholarship.org/uc/item/9g3837v1","pdf_url":null,"source":{"id":"https://openalex.org/S4306400115","display_name":"eScholarship (California Digital Library)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801248553","host_organization_name":"California Digital Library","host_organization_lineage":["https://openalex.org/I2801248553"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Chu, Benjamin. (2009). Evaluating Economizer Use In Data Centers. Berkeley Scientific Journal, 13(1). Retrieved from: http://www.escholarship.org/uc/item/9g3837v1","raw_type":"article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5690000057220459,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W1554056561","https://openalex.org/W1565381879","https://openalex.org/W2143023345","https://openalex.org/W1584579841","https://openalex.org/W2959116273","https://openalex.org/W2525933050","https://openalex.org/W7099433091","https://openalex.org/W2541112018","https://openalex.org/W2055997439","https://openalex.org/W2602466705"],"abstract_inverted_index":{"An":[0],"emerging":[1],"technology":[2],"to":[3,50,92,111],"alleviate":[4],"rising":[5],"energy":[6,45],"demands":[7],"for":[8,25,62,135],"data":[9,63,81,140],"centers":[10],"are":[11,119],"economizers,":[12],"which":[13,41,125],"turn":[14],"off":[15],"the":[16,34,37,53,70,80,106,117,122,136],"power":[17],"consuming":[18],"chillers":[19],"and":[20,77],"bring":[21],"in":[22,29,113,138],"outside":[23,78,114],"air":[24,31,55],"cooling.":[26],"However,":[27,116],"contaminants":[28],"outdoor":[30],"can":[32,42],"lower":[33],"reliability":[35],"of":[36,57,69,79],"electronics":[38],"through":[39],"corrosion,":[40],"negate":[43],"any":[44],"savings.":[46],"This":[47],"experiment":[48],"seeks":[49],"determine":[51],"if":[52],"indoor":[54,101],"quality":[56],"economizer":[58,107,128],"systems":[59],"is":[60,98,108],"suitable":[61],"center":[64],"use.":[65],"The":[66],"mass":[67],"concentrations":[68,103,118],"particulate":[71],"matter":[72],"were":[73,87],"measured":[74],"both":[75],"inside":[76],"center,":[82],"using":[83,89],"aerosol":[84],"instruments.":[85],"Particles":[86],"captured":[88],"collection":[90],"filters,":[91],"identify":[93],"their":[94],"chemical":[95],"properties.":[96],"It":[97],"shown":[99],"that":[100,127],"particle":[102],"rise":[104],"when":[105],"operating,":[109],"due":[110],"bringing":[112],"air.":[115],"well":[120],"below":[121],"ASHRAE":[123],"standard,":[124],"confirms":[126],"use":[129],"does":[130],"not":[131],"pose":[132],"a":[133,139],"risk":[134],"servers":[137],"center.":[141]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2026-09-27T08:07:27.782135","created_date":"2016-06-24T00:00:00"}
