{"id":"https://openalex.org/W112464530","doi":null,"title":"Design of a static time-overcurrent relay as affected by its application","display_name":"Design of a static time-overcurrent relay as affected by its application","publication_year":1976,"publication_date":"1976-01-01","ids":{"openalex":"https://openalex.org/W112464530","mag":"112464530"},"language":"en","primary_location":{"id":"mag:112464530","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/5413364-design-static-time-overcurrent-relay-affected-its-application","pdf_url":null,"source":{"id":"https://openalex.org/S4306523257","display_name":"Proc. Am. Power Conf.; (United States)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Proc. Am. Power Conf.; (United States)","raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5031154766","display_name":"R.C. Manley","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"R.C. Manley","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5031760899","display_name":"L.J. Powell","orcid":"https://orcid.org/0000-0001-9954-147X","observed_orcids":["https://orcid.org/0000-0001-9954-147X"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"L.J. Powell","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.01465798,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"38","issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13093","display_name":"Electric Power Systems and Control","score":0.0003000000142492354,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/overcurrent-protection","display_name":"overcurrent protection","score":0.843999981880188},{"id":"https://openalex.org/keywords/electromechanical-relays","display_name":"electromechanical relays","score":0.9070000052452087},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"power system protection","score":0.7720000147819519}],"concepts":[{"id":"https://openalex.org/C47949032","wikidata":"https://www.wikidata.org/wiki/Q663542","display_name":"Overcurrent","level":3,"score":0.9227033853530884},{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.8972659707069397},{"id":"https://openalex.org/C2780945871","wikidata":"https://www.wikidata.org/wiki/Q194274","display_name":"Backup","level":2,"score":0.8609135150909424},{"id":"https://openalex.org/C2412688","wikidata":"https://www.wikidata.org/wiki/Q503732","display_name":"Protective relay","level":4,"score":0.6196737885475159},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5651021003723145},{"id":"https://openalex.org/C183912175","wikidata":"https://www.wikidata.org/wiki/Q4293157","display_name":"Digital protective relay","level":5,"score":0.5174208879470825},{"id":"https://openalex.org/C79997944","wikidata":"https://www.wikidata.org/wiki/Q260662","display_name":"Solid-state relay","level":4,"score":0.47443047165870667},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4573483169078827},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.41211003065109253},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3256024122238159},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.1711176037788391},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.08267265558242798},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.06880074739456177},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:112464530","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/5413364-design-static-time-overcurrent-relay-affected-its-application","pdf_url":null,"source":{"id":"https://openalex.org/S4306523257","display_name":"Proc. Am. Power Conf.; (United States)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Proc. Am. Power Conf.; (United States)","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2077476047","https://openalex.org/W1997731698","https://openalex.org/W2101124359","https://openalex.org/W4247394920","https://openalex.org/W2015262618","https://openalex.org/W2003736709","https://openalex.org/W2120969916","https://openalex.org/W3161506962","https://openalex.org/W7065334497","https://openalex.org/W2300805386"],"abstract_inverted_index":{"The":[0],"design,":[1],"operation,":[2],"uses,":[3],"and":[4,34,72],"performance":[5],"of":[6,47,93,117,141],"the":[7,22,36,48,55,61,79,91,94,114,120],"General":[8],"Electric":[9],"Type":[10],"SFC":[11,24,62,80,121],"static":[12,81,122],"time":[13],"overcurrent":[14,25,64,82,89],"relay":[15,26,37,83,95,123],"are":[16,96],"reviewed.":[17],"It":[18,102],"is":[19,103],"shown":[20],"that":[21,105],"solid-state":[23],"represents":[27],"a":[28,39],"significant":[29],"advance":[30],"in":[31,54,130,139],"protective":[32],"relaying":[33],"offers":[35],"engineer":[38],"new":[40],"tool":[41],"with":[42,57,69,73,119],"which":[43],"to":[44,98,110],"overcome":[45],"some":[46],"application":[49],"difficulties":[50],"he":[51],"has":[52],"faced":[53],"past":[56],"electromechanical":[58,88,106],"relays.":[59],"With":[60],"relay,":[63],"protection":[65],"can":[66,136],"be":[67,111,137],"accomplished":[68],"greater":[70,134],"precision":[71],"reduced":[74],"backup":[75],"clearing":[76],"times.":[77],"Because":[78],"costs":[84],"more":[85],"than":[86],"conventional":[87],"relays,":[90],"benefits":[92],"subject":[97],"careful":[99],"economic":[100],"analysis.":[101],"expected":[104],"relays":[107],"will":[108],"continue":[109],"satisfactory":[112],"for":[113,128],"vast":[115],"majority":[116],"applications,":[118],"available":[124],"as":[125],"an":[126],"alternative":[127],"use":[129],"situations":[131],"where":[132],"its":[133],"cost":[135],"justified":[138],"terms":[140],"meeting":[142],"specific":[143],"requirements.":[144]},"counts_by_year":[],"updated_date":"2025-10-10T17:16:08.811792","created_date":"2016-06-24T00:00:00"}
