{"id":"https://openalex.org/W102856357","doi":null,"title":"Vibration monitoring for predictive maintenance in central energy plants. Final report","display_name":"Vibration monitoring for predictive maintenance in central energy plants. Final report","publication_year":1993,"publication_date":"1993-09-01","ids":{"openalex":"https://openalex.org/W102856357","mag":"102856357"},"language":"en","primary_location":{"id":"mag:102856357","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/5500901-vibration-monitoring-predictive-maintenance-central-energy-plants-final-report","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5032286836","display_name":"R. Moshage","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"R. Moshage","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5090191158","display_name":"L. Bowman","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"L. Bowman","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5027462504","display_name":"Clay Bethea","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Clay Bethea","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003222434","display_name":"Robert Chesser","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Robert Chesser","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":null,"display_name":"David Burch","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"David Burch","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9229000210762024,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9229000210762024,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.07429999858140945,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.0006000000284984708,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/vibration-analysis","display_name":"vibration analysis","score":0.8149999976158142},{"id":"https://openalex.org/keywords/predictive-maintenance","display_name":"predictive maintenance","score":0.9879999756813049},{"id":"https://openalex.org/keywords/central-heating-plant","display_name":"central heating plant","score":0.9860000014305115},{"id":"https://openalex.org/keywords/rotating-machinery","display_name":"rotating machinery","score":0.8700000047683716},{"id":"https://openalex.org/keywords/equipment-failure-prediction","display_name":"equipment failure prediction","score":0.8519999980926514},{"id":"https://openalex.org/keywords/vibration-monitoring","display_name":"vibration monitoring","score":0.6069999933242798},{"id":"https://openalex.org/keywords/equipment-downtime-reduction","display_name":"equipment downtime reduction","score":0.503000020980835}],"concepts":[{"id":"https://openalex.org/C180591934","wikidata":"https://www.wikidata.org/wiki/Q1253369","display_name":"Downtime","level":2,"score":0.9510623812675476},{"id":"https://openalex.org/C70452415","wikidata":"https://www.wikidata.org/wiki/Q3182448","display_name":"Predictive maintenance","level":2,"score":0.8746963143348694},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6478713154792786},{"id":"https://openalex.org/C198394728","wikidata":"https://www.wikidata.org/wiki/Q3695508","display_name":"Vibration","level":2,"score":0.6399009227752686},{"id":"https://openalex.org/C4402595","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Planned maintenance","level":2,"score":0.607895016670227},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5807756185531616},{"id":"https://openalex.org/C24090081","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Preventive maintenance","level":2,"score":0.4823698103427887},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.47277024388313293},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.41405779123306274},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3349281847476959},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:102856357","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/5500901-vibration-monitoring-predictive-maintenance-central-energy-plants-final-report","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W1516451032","https://openalex.org/W7095774232","https://openalex.org/W2022430891","https://openalex.org/W2472255087","https://openalex.org/W7010237607","https://openalex.org/W2947052973","https://openalex.org/W161064361","https://openalex.org/W1666042525","https://openalex.org/W992395267","https://openalex.org/W2902395190"],"abstract_inverted_index":{"Equipment":[0],"maintenance":[1,43,144,172],"and":[2,58,67,123,150,167],"unexpected":[3],"downtime":[4,100],"resulting":[5],"from":[6,36,141],"equipment":[7,93,103,137,168],"failure":[8],"can":[9,74,84,107],"make":[10],"up":[11],"a":[12,20,112,119,142,157],"significant":[13],"part":[14],"of":[15,18,39],"the":[16,30,37,152],"cost":[17],"running":[19],"central":[21],"heating":[22,177],"plant":[23,136],"(CHP).":[24],"As":[25],"with":[26,50],"most":[27],"rotating":[28,116],"equipment,":[29,117],"machinery":[31],"in":[32],"CHPs":[33],"often":[34],"suffers":[35],"effects":[38],"vibration.":[40],"A":[41],"predictive":[42,143,171],"program":[44,145,158],"uses":[45,147],"vibrational":[46,72],"analysis":[47,73,106],"to":[48,63,102,121,154],"deal":[49],"potential":[51],"vibration":[52,56,69,148],"problems":[53],"by":[54,59],"monitoring":[55],"electronically,":[57],"using":[60],"regular":[61],"measurements":[62],"distinguish":[64],"between":[65],"normal":[66],"exceptional":[68],"signals.":[70],"Since":[71],"help":[75],"predict":[76],"component":[77],"failure,":[78],"those":[79],"parts":[80],"identified":[81,133],"as":[82,111,118],"defective":[83],"be":[85,109],"scheduled":[86],"for":[87,115,159,170],"repair":[88],"or":[89],"replacement":[90],"during":[91,97],"planned":[92],"shutdowns,":[94],"rather":[95],"than":[96],"costly":[98],"emergency":[99],"due":[101],"failure.":[104],"Vibrational":[105],"also":[108,164],"used":[110],"tuning":[113],"device":[114],"way":[120],"pinpoint":[122],"reduce":[124],"machine":[125],"inefficiencies,":[126],"thus":[127],"reducing":[128],"operating":[129],"costs.":[130],"This":[131,162],"study":[132],"specific":[134],"CHP":[135],"that":[138,146],"could":[139],"benefit":[140],"analysis,":[149,175],"outlined":[151],"steps":[153],"implement":[155],"such":[156],"Army":[160],"CHPS.":[161],"report":[163],"lists":[165],"vendors":[166],"specifications":[169],"systems.":[173],"Vibration":[174],"Central":[176],"plants,":[178],"Predictive":[179],"maintenance.":[180]},"counts_by_year":[],"updated_date":"2026-09-29T14:09:16.559479","created_date":"2016-06-24T00:00:00"}
